BACKGROUND AND PURPOSE Risk factors for acute ischemic stroke following flow-diverter treatment of intracranial aneurysms are poorly understood. Using the International Retrospective Study of Pipeline Embolization Device (IntrePED) registry, we studied demographic, aneurysm, and procedural characteristics associated with postoperative acute ischemic stroke following Pipeline Embolization Device (PED) treatment. MATERIALS AND METHODS We identified patients in the IntrePED registry with post-PED-treatment acute ischemic stroke. The rate of postoperative acute ischemic stroke was determined by demographics, comorbidities, aneurysm characteristics, and procedure characteristics (including anticoagulation use, platelet testing, number of devices used, sheaths, and so forth). Categoric variables were compared with χ(2) testing, and continuous variables were compared with the Student t test. Odds ratios and 95% confidence intervals were obtained by using univariate logistic regression. Multivariate logistic regression analysis was used to determine which factors were independently associated with postoperative stroke. RESULTS Of 793 patients with 906 aneurysms, 36 (4.5%) patients had acute ischemic stroke. Twenty-six (72.2%) strokes occurred within 30 days of treatment (median, 3.5 days; range, 0-397 days). Ten patients died, and the remaining 26 had major neurologic morbidity. Variables associated with higher odds of acute ischemic stroke on univariate analysis included male sex, hypertension, treatment of MCA aneurysms, treatment of fusiform aneurysms, treatment of giant aneurysms, and use of multiple PEDs. However, on multivariate analysis, the only one of these variables independently associated with stroke was treatment of fusiform aneurysms (OR, 2.74; 95% CI, 1.11-6.75; P = .03). Fusiform aneurysms that were associated with stroke were significantly larger than those not associated with stroke (mean, 24.5 ± 12.5 mm versus 13.6 ± 6.8 mm; P < .001). CONCLUSIONS Ischemic stroke following PED treatment is an uncommon-but-devastating complication. Fusiform aneurysms were the only variable independently associated with postoperative stroke.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device.

BACKGROUND AND PURPOSE Spontaneous intraparenchymal hemorrhage is a dreaded complication of unknown etiology following flow-diversion treatment. Using the International Retrospective Study of the Pipeline Embolization Device registry, we studied demographic, aneurysm, and procedural characteristics associated with intraparenchymal hemorrhage following Pipeline Embolization Device treatment. M...

متن کامل

CASE SERIES Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study

Background and purpose The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic ...

متن کامل

International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study.

BACKGROUND AND PURPOSE Flow diverters are increasingly used in the endovascular treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates following Pipeline Embolization Device placement for intracranial aneurysm treatment in a real-world setting. MATERIALS AND METHODS We retrospectively evaluated all patients with intracranial aneurysms treated with the Pipe...

متن کامل

Treatment of unruptured intracranial aneurysms with the pipeline embolization device.

The pipeline embolization device (PED; ev3 Endovascular, Plymouth, MN, USA) is a flow-diverter used in the endovascular treatment of intracranial aneurysms, particularly those with unfavorable configurations. It causes progressive flow redirection leading to aneurysm thrombosis. This study aimed to present a systematic review of the published literature on the clinical outcomes of PED. A Medlin...

متن کامل

Use of Platelet Function Testing Before Pipeline Embolization Device Placement: A Multicenter Cohort Study.

BACKGROUND AND PURPOSE Thromboembolic complications constitute a significant source of morbidity after neurointerventional procedures. Flow diversion using the pipeline embolization device for the treatment of intracranial aneurysms necessitates the use of dual antiplatelet therapy to reduce this risk. The use of platelet function testing before pipeline embolization device placement remains co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2016