Performance characteristics of seven automated CA 125 assays.

نویسندگان

  • Shella K Mongia
  • Mindy L Rawlins
  • William E Owen
  • William L Roberts
چکیده

Cancer antigen 125 (CA 125) is a high-molecular-mass glycoprotein that is used as a tumor marker to monitor disease progression and response to therapy and in early detection of recurrence after treatment for ovarian cancer. The Access 2 (Beckman Coulter, Brea, CA), ADVIA Centaur (Bayer Diagnostics, Tarrytown, NY), ARCHITECT i2000 (Abbott Diagnostics, Abbott Park, IL), AxSYM (Abbott Diagnostics), Elecsys 2010 (Roche Diagnostics, Indianapolis, IN), IMMULITE 2000 (Diagnostic Products, Los Angeles, CA), and VITROS ECi (Ortho Clinical Diagnostics, Raritan, NJ) assays for CA 125 were evaluated for detection limit, dilution linearity, imprecision, correlation, and reference intervals. The maximum average deviation from target recoveries for dilution linearity studies ranged from 3.7% for the ADVIA Centaur to 18.2% for the IMMULITE 2000. Imprecision studies yielded total coefficients of variation of 2.0% to 8.3% at CA 125 concentrations of 35 and 114 U/mL (35 and 114 kU/L). Method comparison studies revealed good agreement with the VITROS ECi comparison method, with slopes ranging between 0.88 to 1.19 and correlation coefficients of more than 0.95. All methods show acceptable performance characteristics and generally compare well. However, for some samples, substantial differences exist between methods, necessitating parallel testing when introducing a new method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of seven immunoassays for the quantification of CA 125 antigen in serum.

Seven CA 125 immunoassays were compared for their clinical performance. CA 125 concentrations were determined in 289 serum samples obtained from women with benign pelvic tumors (samples from 98 patients) and patients with various cancers (samples from 111 patients). In the range of 0-1000 kilounits/L, all assays tested were linearly correlated, with correlation coefficients ranging from 0.89 to...

متن کامل

Evaluation of the UniCel™ DxI 800 Immunoassay Analyzer in Measuring Five Tumor Markers

PURPOSE Tumor marker concentrations in a given specimen measured by different analyzers vary according to assay methods, epitopes for antibodies used, and reagent specificities. Although great effort in quality assessment has been instituted, discrepancies among results from different analyzers are still present. We evaluated the assay performance of the UniCel™ DxI 800 automated analyzer in me...

متن کامل

Comparison of an immunoradiometric and an immunoluminometric assay for the evaluation of the tumour associated antigens CA 19-9 and CA 125.

We evaluated the levels of CA 19-9 and CA 125 in the sera of healthy individuals, patients with non-neoplastic diseases known to produce elevated serum concentrations of CA 19-9 and CA 125, and patients with malignant tumours. The serum concentrations determined with an immunoradiometric assay (IRMA) and an immunoluminometric assay (ILMA) were compared. The accuracy was determined (as far as th...

متن کامل

Monoclonal antibody immunoradiometric assay for an antigenic determinant (CA 125) associated with human epithelial ovarian carcinomas.

CA 125 is an antigenic determinant expressed by greater than 80% of nonmucinous epithelial ovarian carcinomas. An immunoradiometric assay has been developed using a murine monoclonal antibody (OC125) to quantitate CA 125 in human serum. This immunoradiometric assay was optimized for specificity, sensitivity, and performance characteristics. Using a simultaneous immunoradiometric assay, the mean...

متن کامل

Monoclonal Antibody Immunoradiometric Assay for an Antigenic Determinant (CA 125) Associated with Human Epithelial Ovarian Carcinomas1

CA 125 is an antigenic determinant expressed by greater than 80% of nonmucinous epithelial ovarian carcinomas. An immunoradiometric assay has been developed using a murine mono clonal antibody (OC125) to quantitate CA 125 in human serum. This immunoradiometric assay was optimized for specificity, sensitivity, and performance characteristics. Using a simultane ous immunoradiometric assay, the me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 125 5  شماره 

صفحات  -

تاریخ انتشار 2006