Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

نویسندگان

  • Sascha Geidel
  • Sergio Peransi Llopis
  • Manuel Rodrigo
  • Graciela de Diego-Castilla
  • Antonio Sousa
  • Jörg Nestler
  • Thomas Otto
  • Thomas Gessner
  • Victor Parro
چکیده

While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The New Design and Simulation of an Optical Add Drop Filter Based On Hexagonal Photonic Crystal Single Ring Race Track Resonator

In this paper, using annular resonator we have designed an adding and dropping filter light based ontwo-dimensional photonic crystals. The shape of ring resonator filter adding and dropping that wehave proposed is Race Track. This filter has a hexagonal lattice structure of silicon bars withrefractive index 3/46 that is located in the context of air with refractive index 1. Transmissionefficien...

متن کامل

Analytical Study of Optical Bi-Stability of a Single-Bus Resonator Based on InGaAs Micro-Ring Array

In this paper, for the first time to our knowledge, we investigate the optical bi-stability in a compact parallel array of micro- ring resonators with 5μm radius, induced by optical nonlinearity. Due to the nature of perfect light confinement, resonance and accumulation process in a ring resonator, optical nonlinear effects, even at small optical power of a few milliwatts in this structure are ...

متن کامل

ساختار مد طولی برای تشدیدگر حلقوی ناهم سطح

 The structure of longitudinal modes of a passively Q-switched, non-planar unidirectional ring-resonator,with Nd:YAG active medium is described in this article. Two different techniques are used to study the longitudinal mode structure of the laser resonator. At first, the fast-fourier transform technique is applied for analyzing the mode beating of the optical fields by intensity frequency str...

متن کامل

Two-curve-shaped biosensor using photonic crystal nano-ring resonators

We design a novel nano-ring resonator using two-dimensional photonic crystal (2D-PhC), for bio-sensing applications. The structure of biosensor is created by two-curve-shaped ring resonator which sandwiched by two waveguides. These are configured by removing one row of air holes. The refractive index of sensing hole is changed by binding an analyte. Hence, intensity of the transmission spectrum...

متن کامل

A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips.

We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment toleran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Micromachines

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2016