Technical performance of colonoscopy -- multicenter study in university and non-university centers of Romania.

نویسندگان

  • I Sporea
  • A Popescu
  • M Diculescu
  • V Stoica
  • G Constantinescu
  • C Cijevschi Prelipcean
  • A Seicean
  • O Pascu
  • M Jinga
  • N Tudor
  • R Voiosu
  • D Dobru
  • A Săftoiu
  • S Vălean
  • E Miuţescu
  • L Bancu
  • S Băţagă
  • D Dumitraşcu
  • C Brisc
  • O Frăţilă
  • I Raţiu
  • L Pienar
  • R Şirli
  • B Miuţescu
چکیده

UNLABELLED The aim of the paper was to evaluate the national availability of colonoscopy and the quality parameters of this procedure in our country. MATERIAL AND METHOD During a 6 months period (01.07- 31.12.2009), we performed a prospective multicenter study in which 76 centers were invited to respond to a questionnaire regarding colonoscopy, 39 centers agreeing to participate. We assessed: the number of colonoscopies, the number of total colonoscopies and the causes of incomplete colonoscopies. RESULTS During the study period, 16,083 colonoscopies were performed, 12,294 (76.4%) of them total colonoscopies. In 1,191 cases, stenosis was the cause of incomplete colonoscopy. If we consider this an objective reason for an incomplete colonoscopy, there were 12,294 total colonoscopies (82.4%). Comparing university centers with non-university ones, the proportion of total colonoscopies was 10,400/12,475 (83.4%) vs. 1,894/2,417 (78.4%) (p less then 0.0001). However, comparing the present study with previous ones, performed in 2003 and 2007, the proportion of total colonoscopies increased from 70.5% to 76.9% and 82.4% respectively (2003 vs. 2007 p less then 0.0001; 2007 vs. 2009 p less then 0.0001), while the quality difference between university and non-university hospitals persisted. CONCLUSIONS the quality of colonoscopy in Romania increased in the last 5 years, while the quality difference between university and non-university hospitals persisted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Vitamin B12 and Nitrous Oxide Neurotoxicity in Operating Room Staff and other Hospital Staff: A Multicenter Study

Background and purpose: Nitrous oxide (N2O) is an anesthetic widely used in operating rooms. Chronic exposure to N2O causes decrease in mental performance, peripheral neuropathy, and polyneuropathy. The aim of this study was to compare neurological complications caused by N2O exposure between operating room staff and other hospital staff. Materials and methods: In this multicenter cohort study...

متن کامل

Hysteretic Type Behaviors of the Complex Fluids via Non-differentiability

1 “Gr. T. Popa” University of Medicine and Pharmacy, Surgery Department, “Sf. Spiridon” Hospital, University str. no. 16, 700115, Iaşi, Romania 2 “Gr. T. Popa” University of Medicine and Pharmacy, Faculty of Pharmacy, Department of Pharmaceutical Technology, University str. no 16, 700115, Iaşi, Romania 3 “Prof. Dr. Nicolae Oblu” Emergency Clinical Hospital, Ateneului 2, Iaşi 700309, Romania 4 “...

متن کامل

Kinematics and fuzzy control of ISOGLIDE3 medical parallel robot

S.-D. Stan*, R. Bălan**, V. Mătieş***, C. Rad**** *Technical University of Cluj-Napoca, C. Daicoviciu no. 15, 400020 Cluj-Napoca, Romania, E-mail: [email protected] **Technical University of Cluj-Napoca, C. Daicoviciu no. 15, 400020 Cluj-Napoca, Romania, E-mail: [email protected] ***Technical University of Cluj-Napoca, C. Daicoviciu no. 15, 400020 Cluj-Napoca, Romania, E-mail: matiesvistria...

متن کامل

Liquid-liquid equilibrium data prediction using large margin nearest neighbor

Guanidine hydrochloride has been widely used in the initial recovery steps of active protein from the inclusion bodies in aqueous two-phase system (ATPS). The knowledge of the guanidine hydrochloride effects on the liquid-liquid equilibrium (LLE) phase diagram behavior is still inadequate and no comprehensive theory exists for the prediction of the experimental trends. Therefore the effect the ...

متن کامل

Approximation theorems for fuzzy set multifunctions in Vietoris topology. Physical implications of regularity

n this paper, we consider continuity properties(especially, regularity, also viewed as an approximation property) for $%mathcal{P}_{0}(X)$-valued set multifunctions ($X$ being a linear,topological space), in order to obtain Egoroff and Lusin type theorems forset multifunctions in the Vietoris hypertopology. Some mathematicalapplications are established and several physical implications of thema...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chirurgia

دوره 108 1  شماره 

صفحات  -

تاریخ انتشار 2013