Stent-graft collapse after endovascular treatment of aortic dissection — case report and review of literature

نویسندگان

  • Tomasz Jakimowicz
  • Michał Macech
  • Amro Alsharabi
  • Jacek Szmidt
چکیده

Application of endovascular method for type B aortic dissection treatment is valuable option compared with open surgery. Despite the lower rate, complications in the endovascular treatment remain important issue. One of them is collapse of the prosthesis. The aim of the study was to present case of stent-graft collapse after endovascular treatment due to aortic dissection and management of this complication, and to highlight the weight of post-operative surveillance. A 44-year old male with resistant hypertension, treated due to aortic dissection 6 years ago, was admitted to Department of General, Vascular and Transplant Surgery of Warsaw Medical University, due to chest pain and decrease of claudication distance to 50 meters since last year. Computed tomography (CT) at admission revealed collapsed proximal part of Zenith stent-graft in descending aorta and fully patent false lumen of dissection. We performed endovascular treatment by additional Zenith stent-graft implantation, successfully restoring blood flow in the true lumen. In one-year observation patient remained asymptomatic and false lumen thrombosed. Stent-graft collapse is one of the rarest complications that occur after the endovascular treatment of the pathologies of thoracic aorta. Small radius of aorta, poor apposition to the inner curve of aorta and exceeding oversizing of the endograft were often reported as the etiology of the complication. Therefore strict CT surveillance is necessary due to wide spectrum of symptoms of collapsed prosthesis. Endovascular management with stent or stent-graft deployment should be first choice treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report

BACKGROUND We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture. CASE PRESENTATION In 7th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG® 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no sig...

متن کامل

Successful Hybrid Treatment of Stent-Graft Migration Caused by Type B Aortic Dissection after Endovascular Aortic Aneurysm Repair: A Case Report

Herein, we report a rare case of type B aortic dissection that occurred after endovascular aortic aneurysm repair (EVAR). A 66-year-old man underwent successful EVAR for an abdominal aortic aneurysm (AAA). Computed tomography (CT) 2 years after EVAR showed a type B aortic dissection with stent-graft migration and AAA expansion. Juxtarenal aortic expansion precluded simple stent-graft placement....

متن کامل

Emergency thoracic aortic stent grafting for acute complicated type B aortic dissection after a previous abdominal endovascular aneurysm repair

We report a case of acute type B aortic dissection with the complication of bowel ischemia and abdominal stent graft compression treated by emergency thoracic aortic stent grafting after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). A 69-year-old male was admitted to our hospital for sudden thoraco-abdominal pain. He had past treatment history of EVAR for AAA half a y...

متن کامل

Acute Type B Dissection Causing Collapse of EVAR Endograft and Iliac Limb Occlusion.

We describe a rare case of acute type B dissection (ATBDs) causing collapse of a previously placed infrarenal stent graft, resulting in acute limb ischemia due to left iliac limb thrombosis in a 59-year-old male. The patient presented with acute back and abdominal discomfort radiating to his back, bilateral buttock stabbing discomfort and left > right thigh and calf rest pain. CT angiography sh...

متن کامل

Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013