Two-dimensional speckle-tracking echocardiography for evaluation of dilative ascending aorta biomechanics

نویسندگان

  • Monika Bieseviciene
  • Jolanta Justina Vaskelyte
  • Vaida Mizariene
  • Rasa Karaliute
  • Vaiva Lesauskaite
  • Raimonda Verseckaite
چکیده

BACKGROUND Two-dimensional (2D) echocardiography is one of the most feasible, noninvasive methods for assessing the aortic diameter and biomechanical changes. We studied possible interfaces between noninvasive biomechanical and speckle-tracking (ST) echocardiographic data from dilated aortas. METHODS Altogether, 44 patients with dilative pathology of ascending aorta (DPAA) were compared with subjects without ascending aortic dilation (diameter <40 mm). DPAA patients formed two groups based on diameter size: group 1, ≤45 mm diameter; group 2, >45 mm. Conventional and 2D-ST echocardiography were performed to evaluate peak longitudinal strain (LS), longitudinal (LD) and transverse (TD) displacement, and longitudinal velocity (VL). Aortic strain, distensibility, elastic modulus, stiffness index β of Valsalva sinuses and ascending aorta were also evaluated. SPSS version 20 was used for all analyses. RESULTS All linear diameters of the ascending aorta were increased in group 2 (>45 mm diameter) (p < 0.05). LD of the anterior aortic wall (p < 0.05) and TD of both aortic walls (p < 0.001) were least in group 2. VL of the posterior and anterior walls diminished in group 2 (p = 0.01). Aortic strain and distensibility were least (p = 0.028 and p = 0.001, respectively) and elastic modulus and stiffness index β values were greatest in group 2, although without statistical significance. CONCLUSIONS Ascending aortas of both DPAA groups had reduced elasticity and increased stiffness. The greatest changes in biomechanical parameters occurred in ascending aortas >45 mm. Longitudinal ascending aortic wall motion was mostly impaired in patients with aortas >45 mm (i.e., anterior aortic wall LD, VL of the posterior and anterior walls. TD of the posterior and anterior aortic walls was significantly lower in >45 mm aortic diameter patients. TD of 5.2 mm could predict aortic dilation >45 mm (area under the curve 0.76, p < 0.001, confidence interval 0.65-0.87; sensitivity 87%; specificity 63%). Greater aortic dilation is associated with reduced aortic stiffness parameters and increased elastic modulus and stiffness index β. Lower LD and LS were associated with less aortic strain and distensibility. There were no significant differences in 2D-ST echocardiographic or stiffness parameters between patients with tricuspid or bicuspid aortic valves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Left ventricular rotational and strain analysis by three-dimensional speckle tracking echocardiography in cardiomyopathies

I. Nemes A, Kalapos A, Domsik P, Forster T. Left ventricular strain reduction is not confinied to the noncompacted segments in noncompaction cardiomyopathy – a threedimensional speckle tracking echocardiographic study. Eur Heart J Cardiovasc Imaging 2013; 14 (Suppl 2.); ii35. II. Nemes A, Kalapos A, Domsik P, Lengyel Cs, Orosz A, Forster T. Relationship between three-dimensional speckle trackin...

متن کامل

Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed ...

متن کامل

Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking.

One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to c...

متن کامل

Evaluation of Subclinical Left Ventricular Systolic Dysfunction in Chronic Asymptomatic Alcoholics by Speckle Tracking Echocardiography

By using two-dimensional speckle tracking echocardiography, we aimed to investigate the structural and functional changes on myocardium in chronic asymptomatic alcoholics without any cardiovascular disease. Forty-one consecutive asymptomatic male alcoholics who were admitted to the outpatient alcoholism unit and 30 age matched healthy male volunteers selected as the control group were enrolled ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017