Anatomical Basis of Pronator Teres for Electromyography Needle Placement Using Ultrasonography

نویسندگان

  • Myung Kyu Park
  • In Yae Cheong
  • Ki Hoon Kim
  • Byung Kyu Park
  • Dong Hwee Kim
چکیده

OBJECTIVE To find the optimal needle insertion site for needle electromyography of the pronator teres (PT) muscle among commonly used sites. METHODS Fifty forearms of 25 healthy subjects were evaluated. Four expected needle insertion points were designated as follows. Point 0 was positioned at the midpoint between the medial epicondyle and medial border of biceps tendon in the elbow crease. Points 1, 2, and 3 were located 2 cm, 3.5 cm and 5 cm distal to point 0, respectively. We assumed that the thickness of PT and the distances between a vertical line from each point to the medial margin of the PT were significant parameters for finding the optimal site. Thus, we measured these parameters through ultrasonographic examination. RESULTS In men, the PT was thickest at point 2, and in women, at point 1. The distance between the expected needle insertion line and medial margin of PT was longest at point 1 in both men and women, and was statistically significant compared to points 2 and 3. Both men and women had neurovascular bundles located lateral to the expected needle insertion line. CONCLUSION The most appropriate and safe needle electromyographic insertional site for the PT is 2-3.5 cm distal to the mid-point between the biceps tendon and medial epicondyle in the elbow crease and the needle should be inserted upward and medial.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is pronator teres reflex valuable for the diagnosis of C6 & C7 radiculopathy?

Background: Neck roots lesion is one of the reasons for cervical and arm pain. A detailed patient evaluation could improve diagnose, reduce imaging requests, and speedy treatment of cervical pain. We tried to estimate the utility of pronator teres reflex in C6 and C7 roots irritation. Methods: Present study is composed of 118 participants including 56 with C6 and C7 lesion and 62 normal contro...

متن کامل

The effect on forearm and shoulder muscle activity in using different slanted computer mice.

BACKGROUND Frequently using non-slanted computer mice will cause musculoskeletal discomfort and symptoms in forearms and shoulders. Ergonomic mice with different slanted angles may have various effects on forearm and shoulder muscle activity. METHODS All of the twelve subjects performed the same text-editing task with the five different slanted mice. The muscle activity of extensor carpi ulna...

متن کامل

Mechanical evaluation of the Pronator Teres rerouting tendon transfer.

We simulated pronator teres rerouting using a three-dimensional biomechanical model of the arm. Simulations comprised the evaluation of changes in muscle length and the moment arm of pronator teres with changes in forearm axial rotation and elbow flexion. The rerouting of Pronator Teres was simulated by defining a path for it through the interosseous membrane with re-attachment to its original ...

متن کامل

The incomplete anterior interosseous nerve syndrome.

The anterior interosseous nerve syndrome involves paralysis of the flexor pollicis longus, flexor digitorum profundus of the index and long fingers, and the pronator quadratus. We have encountered 33 cases of an incomplete syndrome in which only the flexor pollicis longus or the flexor digitorum profundus of the index finger is either paretic or paralyzed. This entity must be distinguished from...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2015