Comparison of two Metal Ion Implantation Techniques for Fabrication of Gold and Titanium Based Compliant Electrodes on Polydimethylsiloxane
نویسندگان
چکیده
This study contrasts the implantation of 25 μm thick Polydimethylsiloxane (PDMS) membranes with titanium and gold ions at 10 keV and 35 keV for doses from 1x10 15 at/cm 2 to 2.5x10 16 at/cm 2 implanted with two different techniques: Filtered Cathodic Vacuum Arc (FCVA) and Low Energy Broad Ion Beam (LEI). The influence of the ion energy, ion type, and implantation tool on the Young’s modulus (E), resistivity and structural properties (nanocluster size and location, surface roughness) of PDMS membranes is reported. At a dose of 2.5x10 16 at/cm 2 and an energy of 10 keV, which for FCVA yields sheet resistance of less than 200 Ω/square, the initial value of E (0.85 MPa) increases much less for FCVA than for LEI. For gold we obtain E of 5 MPa (FCAV) compared to 86 MPa (LEI) and for titanium 0.94 MPa (FCVA) compared to 57 MPa (LEI). Resistivity measurements show better durability for LEI than for FCVA implanted samples and better time stability for gold than for titanium.
منابع مشابه
Metal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers
Here, the use of low-energy metal ion implantation by filtered cathodic vacuum arc to create highly deformable electrodes on polydimethylsiloxane (PDMS) membranes is reported. Implantation leads to the creation of nanometer-size clusters in the first 50 nm below the surface. When the elastomer is stretched, these small clusters can move relative to one another, maintaining electrical conduction...
متن کاملFabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions
In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...
متن کاملIon-implanted compliant and patternable electrodes for miniaturized dielectric elastomer actuators
This article presents metal ion implantation as an alternative technique to fabricate compliant electrodes for small-size dielectric elastomer actuators. When reducing the size of these actuators to below 1 cm, the ability to pattern the electrodes is added to the need for compliance. Metal ion implantation on Polydimethylsiloxane (PDMS) layers allows the creation of conductive and compliant el...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملMultilayer Dielectric Elastomer Actuators with Ion Implanted Electrodes
We present the design, fabrication process and characterization of multilayer miniaturized polydimethylsiloxane (PDMS)-based dielectric elastomer diaphragm actuators. The conductive stretchable electrodes are obtained by lowenergy metal ion implantation. To increase force, decrease the required voltage, and avoid dielectric breakdown, we present here a technique to fabricate multilayer devices ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009