Comparing the efficacy of short-segment pedicle screw instrumentation with and without intermediate screws for treating unstable thoracolumbar fractures

نویسندگان

  • Conglin Ye
  • Zhiping Luo
  • Xiaolong Yu
  • Hucheng Liu
  • Bin Zhang
  • Min Dai
چکیده

It is generally acknowledged that short-segment pedicle screw instrumentation is the preferred surgical method for thoracolumbar fractures. However, the use of short-segment instrumentation with or without intermediate screws at the fracture level remains controversial.We retrospectively evaluated 44 patients (28 men, 16 women) with unstable thoracolumbar fractures. The patients were divided into 2 groups according to the surgical method used. In group 1, 24 patients underwent surgery with a posterior approach via short-segment pedicle screw instrumentation (1 level above and 1 level below the fractured level). In group 2, 20 patients received an additional 2 screws at the fractured vertebrae. Clinical and radiologic parameters were evaluated before surgery and at 1 week, 6 months, and 1 year after surgery.We found no significant difference in the demographic characteristics between the 2 groups. No significant difference was observed in the operative time and intraoperative blood loss between the 2 groups. Clinical outcomes also showed no significant differences between the groups preoperatively or at all follow-up periods. The correction of the Cobb angle (CA) 1 week after surgery was better in group 2, whereas the anterior vertebral body height of the fractured level (AVHF) and compression ratio of the AVHF (AVHFCR) were not significantly different between the 2 groups 1 week after surgery. Moreover, group 2 had better maintenance of restored CA, AVHF, and AVHFCR at the fractured level than did group 1 at 6 months and 1 year postoperatively. In addition, the reduction of mid-sagittal diameter (MSD) of spinal canal 1 week and 1 year after surgery was better in group 2. Besides, bone fragments in the spinal canal have a tendency to be less in group 2 1 week and 1 year after surgery.Reinforcement with intermediate screws for a single thoracolumbar fracture not only enhanced the stability of the internal fixation system, but it was also conducive to the correction of kyphosis and the maintenance of the reduction effects. Furthermore, this method is helpful to restore the spinal canal and reduce the bone fragments in the spinal canal. However, more long-term follow-up studies are needed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pedicle screw instrumentation of thoracolumbar burst fractures: Biomechanical evaluation of screw configuration with pedicle screws at the level of the fracture

BACKGROUND Posterior fixation alone may not be adequate to achieve and maintain burst fracture reduction. Adding screws in the fractured body may improve construct stiffness. This in vitro study evaluates the biomechanical effect of inserting pedicle screws in the fractured body compared with conventional short- and long-segment posterior fixation. METHODS Stable and unstable L2 burst fractur...

متن کامل

Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis

BACKGROUND Traditional one-above and one-below four-screw posterior short-segment instrumentation is used for unstable thoracolumbar burst fractures. However, this method has a high rate of implant failure and early loss of reduction. The purpose of this study was to use finite element (FE) analysis to determine the effect of treating thoracolumbar burst fractures by short-segment pedicle screw...

متن کامل

Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review

OBJECTIVES No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, large...

متن کامل

Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures.

Treatment of unstable thoracolumbar burst fractures remains controversial. Long-segment pedicle screw constructs may be stiffer and impart greater forces on adjacent segments compared with short-segment constructs, which may affect clinical performance and long-term out come. The purpose of this study was to biomechanically evaluate long-segment posterior pedicle screw fixation (LSPF) vs short-...

متن کامل

A comparative analysis of the efficacy of short-segment pedicle screw fixation with that of long-segment pedicle screw fixation for unstable thoracolumbar spinal burst fractures

The indications for operative treatment and type of stabilization procedures for the treatment of thoracolumbar burst fracture remain controversial. As surgical reconstruction for the thoracolumbar burst fracture, both long-segment pedicle screw fixation and short-segment pedicle screw fixation including fractured vertebral body have been used widely. The present study evaluated the efficacy of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017