Performance evaluation of a medical robotic 3D-ultrasound imaging system
نویسندگان
چکیده
3D-ultrasound (US) imaging systems offer many advantages such as convenience, low operative costs and multiple scanning options. Most 3D-US freehand tracking systems are not optimally adapted for the quantification of lower limb arterial stenoses because their performance depends on the scanning length, on ferro-magnetic interferences or because they require a constant line of sight with the US probe. Robotic systems represent a promising alternative since they can control and standardize the 3D-US acquisition process for large scanning distances without requiring a specific line of sight. The performance of a new prototype medical robot, in terms of positioning and inter-target accuracies (i.e., difference between measurements and ground truth values) was evaluated with a lower-limb mimicking phantom throughout the robot workspace. The teach/replay repeatability (i.e., difference between taught and replayed points) was also assessed. A mean positioning accuracy between 0.46 mm and 0.75 mm was found on all scanning zones. The mean inter-target distance accuracy varied between 0.26 mm and 0.61 mm. Teach/replay repeatability below 0.20mm was also obtained. Additionally, a 3D reconstruction of in-vitro stenoses was performed with the robotic US scanner. The quantification error of a 80% area reduction (AR) stenosis was 3.0%, whereas it was -0.9% for a less severe 75% AR stenosis. Altogether, these results suggest that the robot may be of value for the clinical evaluation of lower limb vessels over long and tortuous segments starting from the iliac artery down to the popliteal artery below the knee.
منابع مشابه
Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging
This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...
متن کاملAccurate 3D reconstruction of bony surfaces using ultrasonic synthetic aperture techniques for robotic knee arthroplasty
Robotically guided knee arthroplasty systems generally require an individualized, preoperative 3D model of the knee joint. This is typically measured using Computed Tomography (CT) which provides the required accuracy for preoperative surgical intervention planning. Ultrasound imaging presents an attractive alternative to CT, allowing for reductions in cost and the elimination of doses of ioniz...
متن کاملCISUS: An Integrated 3D Ultrasound System for IGT Using a Modular Tracking API
Ultrasound has become popular in clinical/surgical applications, both as the primary image guidance modality and also in conjunction with other modalities like CT or MRI. Three dimensional ultrasound (3DUS) systems have also demonstrated usefulness in image-guided therapy (IGT). At the same time, however, current lack of open-source and open-architecture multi-modal medical visualization system...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملAdaptive beamforming in row-column addressed arrays for 3D ultrasound imaging
In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical image analysis
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2008