Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI
نویسندگان
چکیده
Advances in solid-state photon detectors paved the way to combine positron emission tomography (PET) and magnetic resonance imaging (MRI) into highly integrated, truly simultaneous, hybrid imaging systems. Based on the most recent digital SiPM technology, we developed an MRI-compatible PET detector stack, intended as a building block for next generation simultaneous PET/MRI systems. Our detector stack comprises an array of 8 × 8 digital SiPM channels with 4 mm pitch using Philips Digital Photon Counting DPC 3200-22 devices, an FPGA for data acquisition, a supply voltage control system and a cooling infrastructure. This is the first detector design that allows the operation of digital SiPMs simultaneously inside an MRI system. We tested and optimized the MRI-compatibility of our detector stack on a laboratory test bench as well as in combination with a Philips Achieva 3 T MRI system. Our design clearly reduces distortions of the static magnetic field compared to a conventional design. The MRI static magnetic field causes weak and directional drift effects on voltage regulators, but has no direct impact on detector performance. MRI gradient switching initially degraded energy and timing resolution. Both distortions could be ascribed to voltage variations induced on the bias and the FPGA core voltage supply respectively. Based on these findings, we improved our detector design and our final design shows virtually no energy or timing degradations, even during heavy and continuous MRI gradient switching. In particular, we found no evidence that the performance of the DPC 3200-22 digital SiPM itself is degraded by the MRI system.
منابع مشابه
MRI compatible detector design: experience from the development of a digital SiPM based detector stack for simultaneous PET/MRI
Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany Silicon based photon detectors make it nowadays possible to build highly integrated PET detectors for simultaneous PET/MRI. Although the operating principle of silicon photomultipliers is believed to be insensitive to the strong magnetic fields inside MRI mac...
متن کاملInitial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner.
UNLABELLED The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system base...
متن کاملA compact PET detector module using SiPMs and MVT digitizers
Huazhong University of Science & Technology, Hubei, China Nowadays the simultaneous PET/MRI is being paid more and more attentions. Since MRI provides a high resolution, unsurpassed soft tissue contrast imaging and PET reveal the metabolism progress in molecular level, it is reasonable to believe the PET/ MRI will be a powerful tool to improve the understanding of pathogenesis and mechanism of ...
متن کاملDevelopment of a PET Insert for simultaneously small animal PET/MRI.
Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China PET/MR is a new multi-modality imaging system which provide both structural and functional information with good soft tissue imaging ability and no ionizing radiation. In recent years, PET/MR is under major progress because of the development of silicon photomult...
متن کاملDevelopment of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging
University of Texas MD Anderson Cancer Center, USA It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2016