Reduction of hemolysis without reoperation following mitral valve repair.

نویسندگان

  • Masaru Inoue
  • Bunji Kaku
  • Hounin Kanaya
  • Takio Ohka
  • Mikio Ueda
  • Seki Masahiro
  • Masami Shimizu
  • Hiroshi Mabuchi
چکیده

Hemolytic anemia following mitral valve repair and annular ring placement is uncommon compared with mitral valve replacement. A 60-year-old man, who had undergone mitral valve repair with a Duran ring, developed hemolytic anemia and needed a blood transfusion. Transesophageal echocardiography revealed a paravalvular mitral regurgitation jet colliding with the Duran ring. Most cases of severe hemolysis after mitral valve repair have undergone reoperation, but in the present case study, the hemolysis after mitral valve repair reduced without the need for reoperation, although the paravalvular mitral regurgitation jet continued to collide with the Duran ring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms of hemolysis after mitral valve repair: assessment by serial echocardiography.

OBJECTIVES We sought to determine, using serial echocardiography, the hydrodynamic mechanisms involved in the occurrence of hemolysis after mitral valve repair. BACKGROUND Recently, fluid dynamic simulation models have identified distinct patterns of mitral regurgitant flow disturbances in patients with mitral prosthetic hemolysis that were associated with high shear stress and may therefore ...

متن کامل

Mechanical Hemolysis after Mitral Valve Repair: Report of a Case

A 60-year-old man underwent aortic valve replacement with a bileaflet mechanical valve for aortic regurgitation and mitral valve repair using a prosthetic ring for mitral regurgitation (MR). Intraoperative transesophageal echocardiography (TEE) confirmed no residual MR and a normally functioning aortic prosthetic valve without a paravalvular leak. One week after the operation, transthoracic ech...

متن کامل

Mitral valve repair with "Double Teflon" technique: 10-year results.

OBJECTIVE The purpose of this paper is to present the late clinical results of mitral valve repair with the "Double Teflon" technique. METHODS "Double Teflon" technique consists of a quadrangular resection of the posterior leaflet, annulus plication with "pledgetted" stitches over a Teflon patch, and leaflet suture. Between 1994 and 2003, 133 patients with degenerative mitral insufficiency du...

متن کامل

Main indications and long-term outcomes of reoperation after initial repair of tetralogy of Fallot

Background and Objective: The aim of this study was to analyze our indications, surgical procedures, and clinical outcomes of patients undergoing reoperation after surgical correction of tetralogy of Fallot (TOF). Methods: Thirty seven consecutive patients who underwent reoperation late after intra-cardiac repair of TOF within a period of 10 years were assessed. Results: The most co...

متن کامل

Mitral valve annuloplasty with a bovine pericardial strip--18-year results.

PURPOSE Prosthetic annuloplasty rings are currently used in mitral reconstruction. Posterior annuloplasty with a bovine pericardial strip is a technique largely used in the Heart Institute of University of São Paulo Medical School. The purpose of the study was to analyze the late results of mitral valve repair with posterior annuloplasty using a bovine pericardial strip. METHODS Between Janua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 67 9  شماره 

صفحات  -

تاریخ انتشار 2003