Cardiac output monitoring: a contemporary assessment and review.
نویسندگان
چکیده
OBJECTIVE An increasing number of minimally or noninvasive devices are available to measure cardiac output in the critical care setting. This article reviews the underlying physical principles of these devices in addition to examining both animal and human comparative studies in an effort to allow clinicians to make informed decisions when selecting a device to measure cardiac output. DATA SOURCES Peer-reviewed manuscripts indexed in PubMed. STUDY SELECTION A systematic search of the PubMed database for articles describing the use of cardiac output monitors yielded 1,526 sources that were included in the analysis. DATA EXTRACTION From all published cardiac output monitoring studies reviewed, the animal model, number of independent measurements, and correlation between techniques was extracted. DATA SYNTHESIS Comparative studies in animals and humans between devices designed for measurement of cardiac output and experimental reference standards indicate thermodilution and Doppler-based techniques to have acceptable accuracy across a wide range of hemodynamic conditions, with bioimpedance techniques being less accurate. Thermodilution devices are marginally more accurate than Doppler-based devices but suffer from slower response time, increased invasiveness, and require stable core temperatures, good operator technique, and a competent tricuspid valve. Doppler-based techniques are less invasive and offer beat-to-beat measurements and excellent trending ability, but are dependent on accurate beam alignment and knowledge of aortic cross-sectional area. Studies of newer devices, such as pulse contour analysis, partial rebreathing, and pulse wave velocity, are far less in number and are primarily based on comparisons with thermodilution-based cardiac output measurements. Studies show widely ranging results. CONCLUSION Thermodilution is relatively accurate for cardiac output measurements in both animals and humans when compared to experimental reference standards. Doppler-based techniques appear to have similar accuracy as thermodilution pulmonary artery catheters. Bioimpedance, pulse contour, partial rebreathing, and pulse wave velocity-based devices have not been studied as rigorously; however, the majority of studies included in this analysis point towards decreased accuracy.
منابع مشابه
مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری
Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملNoninvasive continuous cardiac output monitoring in perioperative and intensive care medicine.
The determination of blood flow, i.e. cardiac output, is an integral part of haemodynamic monitoring. This is a review on noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. We present the underlying principles and validation data of the following technologies: thoracic electrical bioimpedance, thoracic bioreactance, vascular unloading technique, pulse...
متن کاملCardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?
Transesophageal echocardiography offers a noninvasive technique for the continuous monitoring of cardiac performance. The combination of 2-dimensional echocardiography and Doppler velocitometry provide assessment of cardiac anatomy, valve function and, ventricular loading conditions. Although transesophageal echocardiography has become accepted for perioperative monitoring, it is typically used...
متن کاملNon-invasive hemodynamic monitoring in trauma patients
BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department...