We report the accuracy, imprecision, total analytical errors, and patient misclassification errors for cholesterol measured from capillary whole blood, venous whole blood, and venous plasma samples by five devices used in public cholesterol screening environments: Reflotron, Vision, Ektachem DT-60, QuickRead, and Liposcan. None of the methods met the National Cholesterol Education Program (NCEP) performance recommendations of 3% CV with 3% bias. The Vision and Reflotron methods used with venous samples gave individual results with total errors consistent with a combined CV and bias in the 4-5% range; capillary blood samples had total errors > 5% (combined CV and bias criteria). The DT-60 performance was near the 5% total error criterion for capillary samples and was > 5% for venous samples. Misclassification of individuals into desirable or referral groups for venous samples was as great as 5.1% for the DT-60, 5.7% for the Vision, and 7.1% for the Reflotron. Misclassifications for capillary blood samples were as great as 6.7%, 18.3%, and 14.1% for DT-60, Vision, and Reflotron, respectively. The QuickRead and Liposcan results were substantially poorer than those obtained by the other methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol.

BACKGROUND Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). METHODS The total error (TE) of HDL-cholesterol measurements was assessed in native human sera by 25 Dutch clinical chemistry laboratories. Concomitantly, the suitability of...

متن کامل

Quantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics

Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...

متن کامل

The use of biochemical and immunological parameters in nutritional screening and assessment.

OBJECTIVE To evaluate the relationship between serum albumin, total cholesterol and total lymphocyte count with two nutritional assessment methods, to verify if their use is justified in nutritional screening tools. METHODS 101 patients admitted to medical/surgical wards underwent the SGA and the Full Nutritional Assessment (FNA). Blood test which included serum albumin, total cholesterol and...

متن کامل

Effect of analytical error on the assessment of cardiac risk by the high-sensitivity C-reactive protein and lipid screening model.

BACKGROUND Several prospective epidemiologic studies have demonstrated that high-sensitivity C-reactive protein (hsCRP) is an effective serum marker for cardiac risk assessment. When hsCRP is considered in conjunction with traditional lipid screening, its clinical utility is further increased. In this report, hsCRP, HDL-cholesterol (HDLC), and total cholesterol (TC) assay imprecision is evaluat...

متن کامل

Prevalence and Assessment of the Appropriate Laboratory Indices for Screening of Hemoglobinopathyies in Southern Iranian Newborns

Introduction: Newborn screening is a systematic application of tests for early detection, diagnosis, and treatment of certain genetic or metabolic disorders that may lead to mortality and morbidity if untreated. As stated by WHO, each year over 330,000 babies are born worldwide with a severe form of hemoglobinopathy. Newborn screening for hemoglobinopathies could become one of the most importan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 1993