Histidine Scanning Mutagenesis of Basic Residues of the S4 Segment of the Shaker K+ Channel

نویسندگان

  • Dorine M. Starace
  • Francisco Bezanilla
چکیده

The voltage sensor of the Shaker potassium channel is comprised mostly of positively charged residues in the putative fourth transmembrane segment, S4 (Aggarwal, S.K., and R. MacKinnon. 1996. Neuron. 16:1169-1177; Seoh, S.-A., D. Sigg, D.M. Papazian, and F. Bezanilla. 1996. Neuron. 16:1159-1167). Movement of the voltage sensor in response to a change in the membrane potential was examined indirectly by measuring how the accessibilities of residues in and around the sensor change with voltage. Each basic residue in the S4 segment was individually replaced with a histidine. If the histidine tag is part of the voltage sensor, then the gating charge displaced by the voltage sensor will include the histidine charge. Accessibility of the histidine to the bulk solution was therefore monitored as pH-dependent changes in the gating currents evoked by membrane potential pulses. Histidine scanning mutagenesis has several advantages over other similar techniques. Since histidine accessibility is detected by labeling with solution protons, very confined local environments can be resolved and labeling introduces minimal interference of voltage sensor motion. After histidine replacement of either residue K374 or R377, there was no titration of the gating currents with internal or external pH, indicating that these residues do not move in the transmembrane electric field or that they are always inaccessible. Histidine replacement of residues R365, R368, and R371, on the other hand, showed that each of these residues traverses entirely from internal exposure at hyperpolarized potentials to external exposure at depolarized potentials. This translocation enables the histidine to transport protons across the membrane in the presence of a pH gradient. In the case of 371H, depolarization drives the histidine to a position that forms a proton pore. Kinetic models of titrateable voltage sensors that account for proton transport and conduction are presented. Finally, the results presented here are incorporated into existing information to propose a model of voltage sensor movement and structure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two atomic constraints unambiguously position the S4 segment relative to S1 and S2 segments in the closed state of Shaker K channel.

It is now well established that the voltage-sensing S4 segment in voltage-dependent ion channels undergoes a conformational change in response to varying membrane potential. However, the magnitude of the movement of S4 relative to the membrane and the rest of the protein remains controversial. Here, by using histidine scanning mutagenesis in the Shaker K channel, we identified mutants I241H (S1...

متن کامل

Histidine Scanning Mutagenesis of Basic Residues of the S4 Segment of the Shaker K 1 Channel

The voltage sensor of the Shaker potassium channel is comprised mostly of positively charged residues in the putative fourth transmembrane segment, S4 (Aggarwal, S.K., and R. MacKinnon. 1996. Neuron. 16: 1169–1177; Seoh, S.-A., D. Sigg, D.M. Papazian, and F. Bezanilla. 1996. Neuron. 16:1159–1167). Movement of the voltage sensor in response to a change in the membrane potential was examined indi...

متن کامل

Voltage-Sensing Residues in the S2 and S4 Segments of the Shaker K+ Channel

The activation of Shaker K+ channels is steeply voltage dependent. To determine whether conserved charged amino acids in putative transmembrane segments S2, S3, and S4 contribute to the gating charge of the channel, the total gating charge movement per channel was measured in channels containing neutralization mutations. Of eight residues tested, four contributed significantly to the gating cha...

متن کامل

Contribution of the S4 Segment to Gating Charge in the Shaker K+ Channel

Voltage-activated ion channels respond to changes in membrane voltage by coupling the movement of charges to channel opening. A K+ channel-specific radioligand was designed and used to determine the origin of these gating charges in the Shaker K+ channel. Opening of a Shaker K+ channel is associated with a displacement of 13.6 electron charge units. Gating charge contributions were determined f...

متن کامل

Voltage-Dependent Proton Transport by the Voltage Sensor of the ShakerK+ Channel

In voltage-dependent ion channels, pore opening is initiated by electrically driven movements of charged residues, and this movement generates a gating current. To examine structural rearrangements in the Shaker K+ channel, basic residues R365 and R368 in the S4 segment were replaced with histidine, and gating currents were recorded. Changes in gating charge displacement with solvent pH reveal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 117  شماره 

صفحات  -

تاریخ انتشار 2001