Cardiac Resynchronization Therapy Leads to Improvements in Handgrip Strength

نویسندگان

  • David R. Warriner
  • Patricia Lawford
  • Paul J. Sheridan
چکیده

BACKGROUND A reduction in skeletal muscle performance measured by handgrip strength is common in heart failure. No trial has investigated the role of cardiac resynchronization therapy, which leads to improvements in cardiac performance, on the function of skeletal muscle in patients with heart failure. METHODS Nineteen patients were recruited, 18 male, age 69 ± 8 years, New York Heart Association class II-IV, QRS duration 173 ± 21 ms and left ventricular ejection fraction 26±8%. Handgrip strength was measured at baseline before, and 6 and 12 months, following cardiac resynchronization therapy. Response was assessed using quality of life questionnaire, 6-minute walk distance, left ventricular end-diastolic volume, and cardiopulmonary exercise testing at the same time points. RESULTS Fourteen patients were identified as responders, demonstrating significant improvements in all four markers of response. There was no significant difference at baseline in left or right handgrip strength between responders and non-responders. Compared to baseline, handgrip strength significantly increased in responders during follow-up, left (34.4 ± 11.4 to 40.3 ± 11.3 kgf, P < 0.001) and right (35.7 ± 12.5 to 42.2 ± 11.5 kgf, P < 0.001) at 12 months. No such improvement was seen in non-responders. CONCLUSIONS This study demonstrates that positive response to cardiac resynchronization therapy is associated with significant gains in handgrip strength, suggesting that cardiac resynchronization therapy may indirectly lead to secondary gains in skeletal muscle function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OCUS ISSUE: CARDIAC RESYNCHRONIZATION THERAPY Normal QRS Duration and Resynchronization

Cardiac resynchronization therapy has been shown to be an effective treatment for patients with systolic ventricular dysfunction, prolonged ( 120 ms) QRS duration, and New York Heart Association (NYHA) functional class III or IV symptoms despite optimal medical therapy. However, studies show that a majority of heart failure patients have QRS duration 120 ms. We have been investigating the poten...

متن کامل

Cardiac resynchronization therapy.

Systolic heart failure is a major problem for Americans today, with 550,000 new cases diagnosed per year, and ultimately contributes to 287,000 deaths annually. While pharmacologic therapy has drastically improved outcomes in patients with systolic heart failure, hospitalizations from systolic heart failure continue to increase and remain a major cost burden. In response to this unmet need, rec...

متن کامل

Twiddling in cardiac resynchronization therapy: 'when length matters'.

We report on a 75-year-old woman who successfully underwent cardiac resynchronization therapy. Two weeks after implantation, right continuous pectoral stimulation appeared. Retraction and dislodgement of the right atrial and right ventricular leads as well as coiling of the three leads around the device generator were observed on chest radiography, but, surprisingly, the left ventricular lead r...

متن کامل

Stimulus Intensity in Left Ventricular Leads and Response to Cardiac Resynchronization Therapy

BACKGROUND Increased left ventricular (LV) stimulus intensity has been shown to improve conduction velocity and cardiac output. However, high-output pacing would shorten device battery life. Our prospective trial analyzed the clinical effects of high- versus low-output LV pacing. METHODS AND RESULTS Thirty-nine patients undergoing initial cardiac resynchronization therapy device implantation ...

متن کامل

Lead extraction: The road to successful cardiac resynchronization therapy.

BACKGROUND Still increasing life expectancy in patients with implanted devices and large number of leads more and more often induce the need to cure the treatment complications or to change especially to cardiac resynchronization therapy (CRT). In order to prevent further complications, the possibility of damaged or redundant leads extraction should be taken into consideration. The aim of the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2016