1 Performance Evaluation of IEC 61850 Process

نویسندگان

  • K. NARENDRA
  • N. PERERA
  • ERLPhase Power
چکیده

The paper presents the performance of a novel distributed bus differential protection scheme, which utilizes independent multi-principle advanced protection algorithms, including differential percent slope, delta phase directional comparison, rate of change of differential (ROCOD) currents, delta phase directional comparison on neutral current differential, and a check zone to secure the electrical bus bars up to three zones (two main and one transfer bus). This bus protection scheme measures currents from conventional CTs, converts them into digital signals and publish them using IEC 61850 process bus based (9-2) sampled values as Merging Unit. It also subscribes the sampled values amongst all the other relay units (within protection scheme) using fiber optic / copper Ethernet communication. High-speed GOOSE messages (IEC 61850, 8-1) is used to monitor the real time Isolator / Circuit Breaker status, enabling dynamic reconfiguration of the CT inputs to different bus protection relay units depending on the load – generation availability. The proposed bus protection scheme does not need any external Ethernet switch for the sampled value (9-2) exchange. Once the sampled values are received by each protection relay unit, they all act as MASTER relays, and all the relays respond (trip/block) simultaneously to the system event. This also adds redundancy into the bus protection scheme. Rigorous validation and testing has been carried out to validate the performance of the relay scheme using a transmission system simulated in a RTDS (Real Time Digital Simulator). The test cases include switching, loading, inrush currents, and extreme CT saturation conditions for external and internal faults. Many test cases to reflect the practical situation such as high impedance faults, evolving faults, and faults on lightly loaded conditions have also been performed and will be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of Phasor Estimator within IEC 61850-9-2 Communication Network

This paper presents performance evaluation of a new architecture for phasor estimation within IEC 61850 substation Process-Bus. To benefit from the raw IEC 61850-9-2 Sampled Measured Values streamed with high sampling rate from various Merging Units at substation bay level, Unsented Kalman Filter is proposed to be utilized in the computation of Phasor at substation process level to enhance the ...

متن کامل

Evaluation of Process to Bay Level Networking Delay in IEC 61850 Substation Communication System

The modern and high-speed Peer-to-Peer IEC 61850 has opened the chance for planning and developing the sampled values that are supported information exchange among IEDs. Over the method bus network, it’s important to comprehend the transmission responsibility and real-time performance of SVs and GOOSE messages for all-digital IEC 61850 station automation systems (SASs) protection applications t...

متن کامل

Impact of IEC 61850-9-2 Standard-Based Process Bus on the Operating Performance of Protection IEDS: Comparative Study

IEC 61850-9-2 is an international substation automation standard that proposes a Process Bus communication network between process level equipment and bay level Intelligent Electronic Devices (IEDs) used for power systems protection and control. This paper considers the drive towards the use of IEC 61850-9-2 Process Bus in substations. The impact of the IEC 61850-9-2 standard on the operating p...

متن کامل

A Software-Defined Networking Model for Smart Transformers with ISO/IEC/IEEE 21451 Sensors

The IEC 61850-advanced smart transformer shows an improved performance in monitoring, controlling, and protecting the devices and equipment in smart substation. However, the heterogeneity, feasibility and network control problems have limited smart transformers in network performance. To address these issues, a software-defined networking model is proposed using ISO/IEC/IEEE 21451 networks. The...

متن کامل

IEC 61850-7-420 based Communication Configuration to Integrate DER to Distribution System

 Abstract— With the increasing deployment of Distributed Energy Resources (DERs) in the distribution system, DERs presents many challenges for smooth and stable operation of the grid. For the effective management of DERs extensive communication between different components of DER and distribution system is required. In an effort to standardize the communication methods and modeling of logical ...

متن کامل

Cyber Security Practical considerations for implementing IEC 62351

Two trends are currently changing substation automation systems: IEC 61850 and the need for increased cyber security. IEC 61850 has gained global acceptance by both vendors as well as customers. Cyber security on the other hand has quickly become one of the most dominant topics for control systems in general and electrical utilities in particular. The combination of the two, securing IEC 61850 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015