Large area APDs for low energy X-ray detection in intense magnetic fields

نویسندگان

  • M. Boucher
  • O. Huot
  • P. E. Knowles
  • L. Ludhova
  • F. Mulhauser
  • F. Kottmann
  • A. Antognini
  • R. Pohl
  • D. Taqqu
چکیده

An experiment to measure the energy difference between the 2S–2P atomic levels (Lamb shift) in muonic hydrogen is being prepared at PSI. Since the energy levels of muonic hydrogen are a factor of 186 more energetic than those of hydrogen, according to the ratio of reduced masses, the transitions lie in the soft X-ray region. The experiment needs long-lived muonic hydrogen in the 2S state. This is achieved by stopping a low energy muon beam in a small volume of low pressure hydrogen in a 5 T magnetic field. A pulsed beam from a tunable laser induces the 2S–2P transition and the 1:9 keV X-ray photons resulting from the 2P–1S deexcitation will be detected. Measuring the coincidences between the laser pulse and the X-ray as a function of the laser wavelength allows us to determine the Lamb shift. In this presentation we will discuss the perspectives of using large area avalanche photodiodes for the direct detection of the Xrays. Compared to gaseous detectors, they are more compact and simpler in operation. They are also insensitive to magnetic fields. r 2003 Elsevier Science B.V. All rights reserved. PACS: 07.85. m; 29.40.Wk; 85.60.Dw; 36.10.Dr

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent progress of avalanche photodiodes in high-resolution X-rays and γ-rays detection

We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and γrays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and ...

متن کامل

Large-Area APDs and Monolithic APD Arrays

In this paper, development of large-area planar avalanche photodiodes (APDs) and monolithic APD arrays for X-ray and scintillation detection is discussed. Single APDs with areas as large as 10 cm have been fabricated and tested with a CsI(Tl) scintillator (3.8 cm diameter, 2.5 cm height). The resolution of the 662-keV photopeak has been measured to be 9% (FWHM). The X-ray detection performance,...

متن کامل

Response of large area avalanche photodiodes to low energy x rays.

For an experiment to study neutron radiative beta-decay, we operated large area avalanche photodiodes (APDs) near liquid nitrogen temperature to detect x rays with energies between 0.2 keV and 20 keV. Whereas there are numerous reports of x ray spectrometry using APDs at energies above 1 keV, operation near liquid nitrogen temperature allowed us to reach a nominal threshold of 0.1 keV. However,...

متن کامل

Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications

Recently developed multipixel Geiger-mode avalanche photodiodes (G-APDs) are very promising candidates for the detection of light in medical imaging instruments (e.g. positron emission tomography) as well as in high-energy physics experiments and astrophysical applications. G-APDs are especially well suited for morpho-functional imaging (multimodality PET/CT, SPECT/CT, PET/MRI, SPECT/MRI). G-AP...

متن کامل

A Magnetar-like Outburst from a High-b Radio Pulsar

Radio pulsars are believed to have their emission powered by the loss of rotational kinetic energy. By contrast, magnetars show intense X-ray and γ-ray radiation whose luminosity greatly exceeds that due to spin-down and is believed to be powered by intense internal magnetic fields. A basic prediction of this picture is that radio pulsars of high magnetic field should show magnetar-like emissio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003