Adaptive Calibration of Imaging Array Detectors

نویسندگان

  • Marco Budinich
  • Renato Frison
چکیده

We present two methods for nonuniformity correlation of imaging array detectors based on neural networks; both exploit image properties to supply lack of calibrations and maximize the entropy of the output. The first method uses a self-organizing net that produces a linear correction of the raw data with coefficients that adapt continuously. The second method employs a kind of contrast equalization curve to match pixel distributions. Our work originates from silicon detectors, but the treatment is general enough to be applicable to many kinds of array detectors like those used in infrared imaging or in high-energy physics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation Calibration of an Extensive Air Shower array, by a logged data set of its small prototype

Alborz observatory is an EAS array in the heights of Alborez mountain chain near Tehran. For the development of the array, more number of detectors is inevitable. The managing the financial resources and achieving the highest efficiency of the array is important for the project. Therefore, Water Cherenkov Detectors has been used for 9 months in the same way as the previous experiment with Scint...

متن کامل

P5.11 Application and Design of Satellite Infrared Spectral Imaging Radiometers with Uncooled Microbolometer Array Detectors

Uncooled array detectors offer a number of advantages for space borne infrared array imaging. The elimination of detector cooling requirements can significantly reduce the size, cost and power requirements systems. Integration of the instrument to a spacecraft is much simplified due to reduced thermal management requirements. An array of detectors permits imaging without mechanical scanning. In...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Automatic and robust calibration of optical detector arrays for biomedical diffuse optical spectroscopy

The design and testing of a new, fully automated, calibration approach is described. The process was used to calibrate an image-guided diffuse optical spectroscopy system with 16 photomultiplier tubes (PMTs), but can be extended to any large array of optical detectors and associated imaging geometry. The design goals were accomplished by developing a routine for robust automated calibration of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Neural computation

دوره 11 6  شماره 

صفحات  -

تاریخ انتشار 1999