Performance Analysis of a Domestic Refrigerator

نویسندگان

  • M. Y. Taib
  • A. A Aziz
  • A. B. S. Alias
چکیده

Refrigerator is one of the home appliance utilizing mechanical vapour compression cycle in it process. Performance of the system becomes main issue and many researches are still ongoing to evaluate and improve efficiency of the system. Therefore, this paper presents the development process of refrigerator test rig and performance analysis of a domestic refrigerator. The experiment platform which called test rig was developed from refrigerator model NRB33TA National brand. The main objective in this study was to obtain performance of the refrigeration system in term of Refrigeration Capacity, Compressor work and Coefficient of Performance (COP) by determining three important parameters during in operating mode which are temperature, pressure and refrigerant flowrate. In the test rig, all temperature probes were connected to thermocouple scanner to measure temperature at particular points on the refrigeration system. Pressure gauges were used to measure pressure and a magnetic flowmeter was used to measure refrigerant flowrate. In order to avoid effects of a changing the measured data, the environmental of testing was controlled according to Association of Home Appliance Manufacturers (AHAM) standard. There are three sets of experiment data were collected in order to evaluate the refrigerator performance. Each data was collected for a cycle of operation for 2 hours. The result shows that the average COP of the refrigeration system using the refrigerator test rig was about 2.7.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Analysis of a Domestic Refrigerator in Malaysia using Experimental Method

Refrigerator is one of the home appliance utilizing mechanical vapour compression cycle in it process. Performance of the system becomes main issue and many researches are still ongoing to evaluate and improve efficiency of the system. Therefore, this paper presents the development process of refrigerator test rig and performance evaluation of a domestic refrigerator that has been used in Malay...

متن کامل

Performance Comparison of Domestic Refrigerator using HFC134a and HFC134a/HC Refrigerant Mixture

An experimental performance comparison study on domestic refrigerator system was conducted and compared with HFC134a and M09 (HFC134a and HC blend (containing 55.2%HC600a and 44.8%HC290 by weight)) mixture refrigerant. The domestic refrigerator system was initially designed to operate with HFC134a.Experimental results showed that the refrigeration capacity of the refrigerant M09 mixture system ...

متن کامل

Artificial Neural Network Involved in the Action of Optimum Mixed Refrigerant (Domestic Refrigerator) (TECHNICAL NOTE)

This analysis principally focuses on the implementation of Radial basis function (RBF) and back propagation (BPA) algorithms for training artificial neural network (ANN) to get the optimum mixture of Hydro fluorocarbon (HFC) and organic compound (Hydrocarbons) for obtaining higher coefficient of Performances (COPs). The thermodynamical properties of mixed refrigerants are observed using REFPROP...

متن کامل

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Domestic refrigerator-freezers are very widely used for food preservation. There is still growing demand especially in developing countries like India. The growth rate in India for domestic refrigerators is about 15 percent. A large inventory of such appliances exists in India. In recent years, an emphasis is paid to improve the energy efficiency of domestic refrigerator-freezers have to reduce...

متن کامل

Thermodynamic Performance Limit and Evaporator Design Considerations for Narm-Based Domestic Refrigerator-Freezer Systems

Non-azeotropic refrigerant mixtures (NARMs) are investigated for a twotemperature level heat exchange process found in a domestic refrigerator-freezer. Ideal (constant air temperature) heat exchange processes are assumed. The results allow the effects of intercooling between the evaporator refrigerant stream and the condenser outlet stream to be examined in a systematic manner. For the conditio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010