Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique
نویسندگان
چکیده
BACKGROUND Linac-based stereotactic radiosurgery or fractionated stereotactic radiotherapy (SRS/FSRT) of multiple brain lesions using volumetric modulated arc therapy (VMAT) is typically performed by a multiple-isocenter approach, i.e. one isocenter per lesion, which is time-demanding for the need of independent setup verifications of each isocenter. Here, we present our initial experience with a new dedicated mono-isocenter technique with multiple non-coplanar arcs (HyperArc™, Varian Inc.) in terms of a plan comparison with a multiple-isocenter VMAT approach. METHODS From August 2017 to October 2017, 20 patients with multiple brain metastases (mean 5, range 2-10) have been treated by HyperArc in 1-3 fractions. The prescribed doses (Dp) were 18-25 Gy in single-fraction, and 21-27 Gy in three-fractions. Planning Target Volume (PTV), defined by a 2 mm isotropic margin from each lesion, had mean dimension of 9.6 cm3 (range 0.5-27.9 cm3). Mono-isocenter HyperArc VMAT plans (HA) with 5 non-coplanar 180°-arcs (couch at 0°, ±45°, ±90°) were generated and compared to multiple-isocenter VMAT plans (RA) with 2 coplanar 360°-arcs per isocenter. A dose normalization of 100%Dp at 98%PTV was adopted, while D2%(PTV) < 150%Dp was accepted. All plans had to respect the constraints on maximum dose to the brainstem (D0.5cm3 < 18 Gy) as well as to the optical nerves/chiasm, eyes and lenses (D0.5cm3 < 15 Gy). HA and RA plans were compared in terms of dose-volume metrics, by Paddick conformity (CI) and gradient (GI) index and by V12 and mean dose to the brain-minus-PTV, and in terms of MU and overall treatment time (OTT) per fraction. OTT was measured for HA treatments, whereas for RA plans OTT was estimated by assuming 3 min. For initial patient setup plus 5 min. For each CBCT-guided setup correction per isocenter. RESULTS Significant variations in favour of HA plans were computed for both target dose indexes, CI (p < .01) and GI (p < .01). The lower GI in HA plans was the likely cause of the significant reduction in V12 to the brain-minus-PTV (p = .023). Although at low doses, below 2-5 Gy, the sparing of the brain-minus-PTV was in favour of RA plans, no significant difference in terms of mean doses to the brain-minus-PTV was observed between the two groups (p = .31). Finally, both MU (p < .01) and OTT (p < .01) were significantly reduced by HyperArc plans. CONCLUSIONS For linac-based SRS/FSRT of multiple brain lesions, HyperArc plans assured a higher CI and a lower GI than standard multiple-isocenter VMAT plans. This is consistent with the computed reduction in V12 to the brain-minus-PTV. Finally, HyperArc treatments were completed within a typical 20 min. time slot, with a significant time reduction with respect to the expected duration of multiple-isocenters VMAT.
منابع مشابه
Abstract ID: 18137 Title: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery
ID: 18137 Title: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery Purpose: To investigate the treatment of multiple brain metastases using stereotactic radiosurgery with single-isocenter volumetric modulated arc therapy (VMAT)...
متن کاملEvaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?
PURPOSE To investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (DCA), and to benchmark it against the well-established multiple isocenter DCA (MIDCA) and volumetric modulated arc therapy (VMAT) approaches. MATERIAL AND METHODS Ten previous...
متن کاملTreatment Plan Technique and Quality for Single-Isocenter Stereotactic Ablative Radiotherapy of Multiple Lung Lesions with Volumetric-Modulated Arc Therapy or Intensity-Modulated Radiosurgery
The aim of this study is to provide a practical approach to the planning technique and evaluation of plan quality for the multi-lesion, single-isocenter stereotactic ablative radiotherapy (SABR) of the lung. Eleven patients with two or more lung lesions underwent single-isocenter volumetric-modulated arc therapy (VMAT) radiosurgery or IMRS. All plans were normalized to the target maximum dose. ...
متن کاملOptimization of multiple-isocenter treatment planning for linac-based stereotactic radiosurgery.
OBJECTIVE Computer-assisted treatment planning for linac-based radiosurgery is still an open research problem, especially for multiple-isocenter procedures, primarily due to its high complexity and computational requirements. This paper focuses on the optimization of multiple-isocenter treatment planning for linac systems, and addresses several important issues associated with multiple isocente...
متن کاملOptimization Algorithm for Single-Isocenter VMAT Stereotactic Radiosurgery for Multiple Brain Metastases
Objectives: Developing an optimal Stereotactic radiosurgery (SRS) plan for multiple brain metastases can be a labor intensive process. Single-isocenter multi-arc volumetrically modulated arc therapy (VMAT) has been used as an SRS technique, in which a Linear Accelerator (Linac) delivers targeted radiation along multiple arc angles as it rotates around the isocenter. Standardized arc angles with...