A Meta-Analysis of Randomized Controlled Trials of Low-Volume Polyethylene Glycol plus Ascorbic Acid versus Standard-Volume Polyethylene Glycol Solution as Bowel Preparations for Colonoscopy

نویسندگان

  • Qingsong Xie
  • Linghui Chen
  • Fengqing Zhao
  • Xiaohu Zhou
  • Pengfei Huang
  • Lufei Zhang
  • Dongkai Zhou
  • Jianfeng Wei
  • Weilin Wang
  • Shusen Zheng
چکیده

BACKGROUND Standard-volume polyethylene glycol (PEG) gut lavage solutions are safe and effective, but they require the consumption of large volumes of fluid. A new lower-volume solution of PEG plus ascorbic acid has been used recently as a preparation for colonoscopy. AIM A meta-analysis was performed to compare the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. STUDY Electronic and manual searches were performed to identify randomized controlled trials (RCTs) that compared the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. After a methodological quality assessment and data extraction, the pooled estimates of bowel preparation efficacy during bowel cleansing, compliance with preparation, willingness to repeat the same preparation, and the side effects were calculated. We calculated pooled estimates of odds ratios (OR) by fixed- and/or random-effects models. We also assessed heterogeneity among studies and the publication bias. RESULTS Eleven RCTs were identified for analysis. The pooled OR for preparation efficacy during bowel cleansing and for compliance with preparation for low-volume PEG plus ascorbic acid were 1.08 (95% CI = 0.98-1.28, P = 0.34) and 2.23 (95% CI = 1.67-2.98, P<0.00001), respectively, compared with those for standard-volume PEG. The side effects of vomiting and nausea for low-volume PEG plus ascorbic acid were reduced relative to standard-volume PEG. There was no significant publication bias, according to a funnel plot. CONCLUSIONS Low-volume PEG plus ascorbic acid gut lavage achieved non-inferior efficacy for bowel cleansing, is more acceptable to patients, and has fewer side effects than standard-volume PEG as a bowel preparation method for colonoscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-volume polyethylene glycol and bisacodyl for bowel preparation prior to colonoscopy: a meta-analysis

BACKGROUND Quality of bowel preparation prior to colonoscopy is essential. Studies have shown a reduced volume of polyethylene glycol (PEG) with bisacodyl may improve visualization and tolerability, but results have varied. Therefore, a meta-analysis was performed to analyze the efficacy of a low-volume PEG bowel preparation with bisacodyl for bowel preparation prior to colonoscopy. METHODS M...

متن کامل

Polyethylene glycol plus ascorbic acid for bowel preparation in chronic kidney disease

The safety of polyethylene glycol plus ascorbic acid has not been fully investigated in patients with renal insufficiency. High-dose ascorbic acid could induce hyperoxaluria, thereby causing tubule-interstitial nephritis and renal failure. This study aims to evaluate the safety and efficacy of polyethylene glycol plus ascorbic acid in patients with chronic kidney disease.We retrospectively revi...

متن کامل

Optimal intake of clear liquids during preparation for afternoon colonoscopy with low-volume polyethylene glycol plus ascorbic acid

BACKGROUND AND STUDY AIMS  The standard colonoscopy preparation regimen in Japan for afternoon procedures is sequential intake of 1 L of polyethylene glycol electrolyte lavage solution containing ascorbic acid (PEG-ASC), 0.5 L of clear liquid, 0.5 L of PEG-ASC, and finally 0.25 L of clear fluids (all at a rate of 0.25 L every 15 min). However, this regimen seems poorly tolerated and complicated...

متن کامل

A Prospective Randomized Controlled Trial of AJG522 versus Standard PEG + E as Bowel Preparation for Colonoscopy

Polyethylene glycol- (PEG-) based bowel preparations for colonoscopies are often poorly tolerated due to the large volumes of fluid intake required. We compared low-volume "modified" PEG + ascorbic acid (AJG522) with standard PEG with electrolytes (PEG+E) in addition to a stimulant laxative and an agent to improve bowel function for the bowel cleansing before colonoscopy to evaluate its efficac...

متن کامل

A Randomized Controlled Trial Evaluating a Low-Volume PEG Solution Plus Ascorbic Acid versus Standard PEG Solution in Bowel Preparation for Colonoscopy

Evaluation of polyethylene glycol electrolyte lavage solution containing ascorbic acid (PEG-ASC) has been controversial in the point of its hyperosmolarity, especially in old population. So we therefore designed the present study to compare the efficacy, acceptability, tolerability, and safety of 1.5 L PEG+ASC and 2 L standard PEG electrolyte solution (PEG-ELS), not only in the general populati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014