Respiratory Motion Prediction with Extended Kalman Filters Based on Local Circular Motion Model
نویسندگان
چکیده
Motion of thoracic and abdominal tumors induced by respiratory motion often exceeds more than one centimeter which can compromise dose conformality significantly. Motionadaptive radiotherapy aims to deliver a conformal dose distribution to a tumor with minimal normal tissue exposure, by compensating for the tumor motion in real time. This requires prediction of respiratory motion to estimate the respiratory movement that has occurred during the system latency due to measurement and control. One of the most successful models for predicting respiratory motion is the local circular motion (LCM) model. It characterizes the local respiratory behavior with a circular motion in an augmented plane and captures the natural evolution of respiratory motion. In this paper, we utilize the first and second-order extended Kalman filters based on LCM model for predicting respiratory motion. We also optimize the parameters of the extended Kalman filters for each trace in an attempt to improve prediction accuracy. Numerical experiments are performed to evaluate and compare prediction accuracy of four different prediction schemes.
منابع مشابه
Real-time prediction of respiratory motion based on a local dynamic model in an augmented space.
Motion-adaptive radiotherapy aims to deliver ablative radiation dose to the tumor target with minimal normal tissue exposure, by accounting for real-time target movement. In practice, prediction is usually necessary to compensate for system latency induced by measurement, communication and control. This work focuses on predicting respiratory motion, which is most dominant for thoracic and abdom...
متن کاملA Survey of Algorithms for Respiratory Motion Prediction in Robotic Radiosurgery
In robotic radiosurgery, a standard six-jointed industrial robot carries a linear accelerator. The accelerator can be moved such as to compensate for respiratory motion. Unfortunately, this motion cannot be compensated perfectly since the motion of the robot lags behind the motion of the target organ by – in systems currently employed clinically – approximately 150 ms. This delay is compensated...
متن کاملA fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study
Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...
متن کاملReal-time prediction and gating of respiratory motion in 3D space using extended Kalman filters and Gaussian process regression network.
The prediction as well as the gating of respiratory motion have received much attention over the last two decades for reducing the targeting error of the radiation treatment beam due to respiratory motion. In this article, we present a real-time algorithm for predicting respiratory motion in 3D space and realizing a gating function without pre-specifying a particular phase of the patient's brea...
متن کاملThe Active Recovery of 3D Motion Trajectories and Their Use in Prediction
This paper describes the theory and real-time implementation using an active camera platform of a method of planar trajectory recovery, and of the use of those trajectories to facilitate prediction over delays in the visual feedback loop. Image-based position and velocity demands for tracking are generated by detecting and segmenting optical flow within a central region of the image, and a proj...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013