First clinical experience with a new flexible low profile metallic stent and delivery system.
نویسندگان
چکیده
We report the first clinical use of a new, flexible, low profile, balloon-expandable metallic stent and delivery system (ACS Multi-Link). The stent, designed in an effort to overcome the shortcoming of existing stents, has a low metal mass, superior scaffolding properties and favourable rheological characteristics. It also allows side branch access and is delivered via an innovative stent catheter. Ten stents were used to treat 10 patients with threatened abrupt closure after balloon angioplasty. All were successfully deployed, with a satisfactory angiographic result in nine. The patient with an unsatisfactory angiographic result proceeded to uneventful coronary bypass surgery. There were no other procedural or in-hospital complications. One patient developed restenosis and one had an intra-cerebral bleed following a fall. This new stent thus appears safe and effective when used to treat threatened abrupt closure. Due to its favourable characteristics, it may be well suited for reduction of restenosis. A multi-centre European registry (WEST) for primary implantation in 100 consecutive patients has now been completed.
منابع مشابه
The INCRAFT AAA Stent Graft System: Placement Accuracy and Customization
An essential feature of any endovascular device used to treat abdominal aortic aneurysms (AAAs) is the ability to accommodate any necessary changes after the delivery system has been introduced. The INCRAFT® AAA Stent Graft System (Cordis Corporation) was designed to solve the limitations of previous-generation endovascular devices, particularly with regard to versatility, accuracy, and real-ti...
متن کاملIncomplete deployment of an expandable metallic stent in a patient with esophageal malignant stenosis.
The use of self expandable metallic stents (SEMS) in the palliation of dysphagia due to malignant esophageal stenosis is a gold standard. Covered stents are used in all cases with overt air-digestive fistula or high potential for fistula development. The procedure is associated with a low incidence of procedure-related complications. We present a case with a major accident which developed durin...
متن کاملLocal drug delivery via a coronary stent with programmable release pharmacokinetics.
BACKGROUND Fixed drug release kinetics and vessel wall partitioning may limit the effectiveness of drug-eluting stents. We report preliminary experience using a new coronary stent with programmable pharmacokinetics. METHODS AND RESULTS A newly designed metallic stent contains honeycombed strut elements with inlaid stacked layers of drug and polymer. In vitro studies evaluated recipes for load...
متن کاملImplantation of a self-expandable metallic inverted Y-stent to treat tracheobronchial stenosis in the carinal region: initial clinical experience.
Introduction Tracheobronchial stenoses or fistulas caused by benign or malignant diseases are life-threatening and present as respiratory distress symptoms.Airway stent insertion is an effective and widely used method to manage this condition. When the stenoses or the fistulas exist in the lower trachea,main carina, and main-stem bronchi, the insertion of one hinged stent or angled stent, or tw...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal
دوره 17 3 شماره
صفحات -
تاریخ انتشار 1996