Dosimetric differences among volumetric modulated arc radiotherapy (RapidArc) plans based on different target volumes in radiotherapy of hepatocellular carcinoma
نویسندگان
چکیده
We investigated the dosimetric differences among volumetric-modulated arc radiotherapy (RapidArc, RA) plans designed for various target volumes in hepatocellular carcinoma (HCC). Ten HCC patients underwent 3D-CT scanning at free breathing (FB), 3D-CT at end inspiration hold (EIH) assisted by an Active Breathing Coordinator (ABC), and 4D-CT scanning. Gross tumor volumes (GTVs) were manually contoured on CT images. The individualized internal gross target volume (IGTV(1)) was obtained from 10 GTVs from 4D-CT images. Tumor individual margins were measured from GTV(FB) to IGTV(1). The IGTV(2) was obtained from GTV(FB) by applying individual margins. Four planning target volumes (PTV(1-4)) were obtained from IGTV(1), IGTV(2), GTV(FB), and GTV(EIH), respectively. An RA plan was designed for each of the PTVs (RA(1-4)). One 358° arc was used for PTVs(1-3), while three 135° arcs were used for PTV(4). It was found that PTV(2) and PTV(3) were larger than PTV(1) and PTV(4). The mean values of PTV(3)/PTV(1) and PTV(3)/PTV(4) were 2.5 and 1.9, respectively. The individual margins in the X, Y and Z axial directions varied greatly among these patients. There were no significant differences in the conformal index or homogeneity index among the four RA plans. RA(1) and RA(4) significantly reduced the radiation dose of normal liver tissue compared with RA(2) and RA(3) (P < 0.01). There were no significant differences between the radiation doses of the stomach and duodenum. RapidArc combined with 4D-CT or ABC technology is a promising method in radiotherapy of HCC, and accurately targeted the tumor volume while sparing more normal liver tissue.
منابع مشابه
Dosimetric Comparison and Evaluation of 4 Stereotactic Body Radiotherapy Techniques for the Treatment of Prostate Cancer
PURPOSE The aim of this study was to compare dosimetric characteristics, monitor unit, and delivery efficiency of 4 different stereotactic body radiotherapy techniques for the treatment of prostate cancer. METHODS This study included 8 patients with localized prostate cancer. Dosimetric assets of 4 delivery techniques for stereotactic body radiotherapy were evaluated: robotic CyberKnife, nonc...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملRetrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy
INTRODUCTION This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). METHODS Treatment plan qual...
متن کاملVolumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
BACKGROUND To compare the RapidArc plan for primary hepatocellular carcinoma (HCC) with 3-D conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) plans using dosimetric analysis. METHODS Nine patients with unresectable HCC were enrolled in this study. Dosimetric values for RapidArc, IMRT, and 3DCRT were calculated for total doses of 45~50.4 Gy using 1.8 Gy/day. The parame...
متن کاملPurpose:To investigate the difference in sparing normal liver tissue between 4D-CT and active breathing coordinator (ABC) in the radiotherapy of Hepatocellular carcinoma(HCC) applying RapidArc. Methods:Ten patients with HCC underwent 3D-CT at end inspiration hold(EIH) associated with active breathing coordinator(ABC)
ID: 18059 Title: 4D-CT and Active Breathing Coordinator Play Similar Role in Sparing Normal Liver Tissue in the Radiotherapy of Hepatocellular Carcinoma Purpose:To investigate the difference in sparing normal liver tissue between 4D-CT and active breathing coordinator (ABC) in the radiotherapy of Hepatocellular carcinoma(HCC) applying RapidArc. Methods:Ten patients with HCC underwent 3D-CT at e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 54 شماره
صفحات -
تاریخ انتشار 2013