Effect of micro-roughness produced by TiO2 blasting--tensile testing of bone attachment by using coin-shaped implants.

نویسندگان

  • Hans Jacob Rønold
  • Jan Eirik Ellingsen
چکیده

The aim of the present study was to examine bone response to micro-rough titanium implants. Forty coin-shaped implants were divided into eight groups according to their surface roughness. The first group had electropolished surfaces. The surfaces of implant groups 2-8 were blasted with TiO2 particles with incremental grain sizes ranging from 7.5-12.5 to 270-330 microns. Five implants from each group were placed into the cortical bone of the proximal tibia in New Zealand Black rabbits. To avoid bone overgrowth during the retention phase the implants were fitted into tight polytetrafluoroethylene (PTFE) caps leaving only the flat test surface exposed to bone. The healing period was set to 10 weeks, and implants with attached bone were evaluated using a tensile testing machine. In groups 1-7 a significant correlation between the micro-roughness of the implant surfaces and retention strength was observed. Maximum bone bonding was observed with implants blasted with 180-220 microns grain size (group 7). Blasting with larger TiO2 particles appeared to decrease the effect. The findings suggest that the best grain size of TiO2 particles for optimising retention of titanium implants in cortical bone should be in the 180-220 microns range.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of a coin shaped implant for direct in situ measurement of attachment strength for osseointegrating biomaterial surfaces.

Most animal models currently used to study the retention of implants in bone are influenced by shear forces introduced during the retention test. This is mainly due to the implant design, which most often are cylindrical, conical or threaded. In these models interlocking between bone and implant surface will increase the effect of genuine bone bonding and thus give a false positive outcome. The...

متن کامل

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

The influence of surface treatment on the implant roughness pattern

UNLABELLED An important parameter for the clinical success of dental implants is the formation of direct contact between the implant and surrounding bone, whose quality is directly influenced by the implant surface roughness. A screw-shaped design and a surface with an average roughness of Sa of 1-2 µm showed a better result. The combination of blasting and etching has been a commonly used surf...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces.

OBJECTIVES This study evaluated cytocompatibility and osseointegration of the titanium (Ti) implants with resorbable blast media (RBM) surfaces produced by grit-blasting or XPEED(®) surfaces by coating of the nanostructured calcium. MATERIAL AND METHODS Ti implants with XPEED(®) surfaces were hydrothermally prepared from Ti implants with RBM surfaces in a solution containing alkaline calcium....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomaterials

دوره 23 21  شماره 

صفحات  -

تاریخ انتشار 2002