Implications of the Rician distribution for fMRI generalized likelihood ratio tests.

نویسندگان

  • Arnold J den Dekker
  • Jan Sijbers
چکیده

In functional magnetic resonance imaging (fMRI), the general linear model test (GLMT) is widely used for brain activation detection. However, the GLMT relies on the assumption that the noise corrupting the data is Gaussian distributed. Because the majority of fMRI studies employ magnitude image reconstructions, which are Rician distributed, this assumption is invalid and has significant consequences in case the signal-to-noise ratio (SNR) is low. In this study, we show that the GLMT should not be used at low SNR. Furthermore, we propose a generalized likelihood ratio test for magnitude MR data that has the same performance compared to the GLMT for high SNR, but performs significantly better than the GLMT for low SNR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain activation detection from magnitude fMRI data using a generalized likelihood ratio test

Functional magnetic resonance (fMRI) studies intend to answer neuroscience questions by statistically analyzing a set of acquired images. Thereby, the aim is to determine those regions in the brain image in which the signal changes upon stimulus presentation. Although MR data are intrinsically complex valued, most tests are commonly applied to magnitude MR images, because these images have the ...

متن کامل

An Evaluation of an Adaptive Generalized Likelihood Ratio Charts for Monitoring the Process Mean

When the objective is quick detection both small and large shifts in the process mean with normal distribution, the generalized likelihood ratio (GLR) control charts have better performance as compared to other control charts. Only the fixed parameters are used in Reynolds and Lou’s presented charts. According to the studies, using variable parameters, detect process shifts faster than fixed pa...

متن کامل

BOLD Noise Assumptions in fMRI

This paper discusses the assumption of Gaussian noise in the blood-oxygenation-dependent (BOLD) contrast for functional MRI (fMRI). In principle, magnitudes in MRI images follow a Rice distribution. We start by reviewing differences between Rician and Gaussian noise. An analytic expression is derived for the null (resting-state) distribution of the difference between two Rician distributed imag...

متن کامل

A New Approximation for the Null Distribution of the Likelihood Ratio Test Statistics for k Outliers in a Normal Sample

Usually when performing a statistical test or estimation procedure, we assume the data are all observations of i.i.d. random variables, often from a normal distribution. Sometimes, however, we notice in a sample one or more observations that stand out from the crowd. These observation(s) are commonly called outlier(s). Outlier tests are more formal procedures which have been developed for detec...

متن کامل

On Multivariate Likelihood Ratio Ordering among Generalized Order Statistics and their Spacings

The most of the results obtained about stochastic properties of generalized order statistics and their spacings in the literature are based on equal model parameters. In this paper, with less restrictive conditions on the model parameters, we prove some new multivariate likelihood ratio ordering results between two sub-vectors of GOS's as well as two sub-vectors of $p$-spacings based on two con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 23 9  شماره 

صفحات  -

تاریخ انتشار 2005