Fast Fat Suppression Technique for Adaptive 3D Radial MRI Based on Multidimensional Golden Means

نویسندگان

  • P. Siegler
  • R. W-C. Chan
  • E. Ramsay
  • D. B. Plewes
چکیده

INTRODUCTION Adaptive sampling of k-space allows the reconstruction of images with various spatial and temporal resolutions from the same data set and is therefore suitable for dynamic MRI [1,2]. Golden-angle radial k-space sampling achieves this flexibility in-plane with relatively uniform angular sampling distribution for any time interval using samples incremented by the golden angle, φ = (√5-1)/2⋅180°≈111.25° [3]. To achieve a similar sampling pattern in 3D k-space, this was extended to 3D projection reconstruction (PR) based on multidimensional golden means (“golden 3D-PR”) [4]. The uniform sampling of k-space over time with 2D radial MRI, can be combined with the kspace-weighted image contrast (KWIC) technique [5] to compensate for respiratory motion [6]. As the periodic time intervals in golden angle MRI show an approximately uniform coverage of k-space, uniform filling of KWIC regions in k-space over time is possible. This fact is also valid for golden 3DPR and is used here for fast fat suppression using partial fat saturation [7], where the KWIC regions are filled depending on the time interval between the current projection and the last projection with a fat saturation pulse. MATERIALS AND METHODS In golden 3D PR [4], the first of the higher dimensional golden means (0.4656) determined the kz location while the second (0.6823) determined the in-plane angle of the 3D radial projections. For the partial fat saturation [6], each Rfat-th projection of the golden angle radial scan was preceded by a fat saturation pulse. Using KWIC processing [5], the most central kspace sphere (radius of 10 k-space positions) around the k-space center was filled with the projections which had been acquired a maximum of Rfat/4 repetitions after a fat saturation pulse. In the shell around the central k-space sphere (outer radius of 20 k-space positions) all the projections acquired a maximum of Rfat/2 repetitions after a fat saturation pulse were used. For the rest of k-space all acquired projections were used. The experiments were performed on a high-resolution phantom with a fat compartment. A whole body 1.5T MR scanner (GE Signa Excite) and a fast 3D spoiled gradient echo (fast 3D SPGR) golden PR sequence (TE=4.2ms, TR=9.725ms without fat saturation pulse, TR=19.432ms with fat saturation pulse and FOV = 216×216×216mm) were used for imaging. • Fat recovery with different excitation angles: Data sets were acquired with the 3D golden angle approach (32,000 projections) and Rfat=32 but varying flip angle α. To show the different levels of fat recovery with the different excitation angles, sub-data sets of all the projections acquired during the same repetition after the fat saturation pulse (1,000 projections) were created. The ratio of the mean water and the mean fat signal, both averaged over a region of interest, were determined. For α=9°, KWIC was applied on a data-set with 32,000 projections used for reconstruction. • Different fat saturation ratios: Using α=9°, partial fat saturated data sets were acquired with different fat saturation ratios Rfat. In order to achieve fixed scan-times of 330s and 11s, the number of projections used for reconstruction was varied with Rfat. In addition, fully fat saturated 3D golden angle data sets with these fixed scan-times were acquired and reconstructed. RESULTS As with reordered fat saturation, the choice of flip angle strongly influenced the recovery of the fat signal during the repetitions after a fat saturation pulse (Fig.1). For Rfat=32, an excitation angle of α=9° results in the best water to fat ratios, whereas with higher flip angles the fat recovered more quickly and even overtook the water signal. In the case of α=5° the important first repetitions, which with KWIC would be placed in the central k-space region, showed lower fat saturation levels. The partial fat saturation alone achieved a reduction of the fat signal (Fig. 2a). With KWIC, fat suppression could be further improved (Fig 2b). For the longer scan-time tested (330s – left column of Fig.3), the proposed technique gave fat suppression comparable to full fat saturation. The fat signal increased with time between fat saturation pulses. For the shorter scan-time, the proposed technique allowed more projections to be included in the reconstruction, resulting in a noticeable reduction of undersampling artifacts. DISCUSSION AND CONCLUSIONS The periodic order of the partial fat saturation pulses in partial fat saturation segments the acquired golden 3D-PR data-set into sub-sets with equal fat saturation levels, which covers k-space with approximately uniformity. KWIC can therefore be successfully used to combine golden 3D-PR with partial fat saturation. For images reconstructed with high number of projections, the resulting fat suppression is slightly degraded compared to a fully fat saturated golden 3D-PR. However, the shorter scan-time of the new technique can be used to increase the number of projections in a given time interval, thus allowing the reconstruction of fat suppressed images at very high temporal resolution. REFERENCES [1] Rasche V, et al. MRM 1995;34:754-61 [2] Peters DC, et al. MRM 2000;43:91-101 [3] Winkelmann S, et al. IEEE TMI 2007;26:68-76 [4] Chan RWC, et al. MRM 2008 in press [5] Song HK, et al. MRM 2004;52:815-24 [6] Lin W, et al. MRM 2008;60:1135-46 [7] Desmond KL, et al. JMRI 2007;25:1293-8 Figure 3: Comparison of fully fat saturated golden angle PR and KWIC partial fat saturated golden angle PR with different Rfat. Two different time resolutions were considered by varying the number of projections (right corner of each image) used for reconstruction. Figure 2: One slice through the 3D data set acquired with α=9° and Rfat=32. a) If all projections are used for reconstruction, fat signal remains in the final images. b) KWIC achieves improved fat saturation. Figure 1: Ratio of the average water signal to the average fat signal as a function of the number of repetitions after the fat saturation pulse for different flip angles α. The rough curves for the small α are caused by undersampling artifacts inside the low fat signal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporal Stability of 3D-PR based on Multidimensional Golden Means: Simulation and Implementation

INTRODUCTION Adaptive sampling of k-space allows images in dynamic contrast-enhanced (DCE)-MRI to be reconstructed at various spatial and temporal resolutions from the same dataset. Golden-angle radial kspace sampling achieves this flexibility in-plane with samples incremented by the golden angle, φ = (√5 1)/2 * 180° [1,2]. These projections fill 2D k-space with projections that have a relative...

متن کامل

Adaptive 3D Radial MRI Based on Multidimensional Golden Means for Supine Breast Imaging

INTRODUCTION Supine breast MRI [1] allows imaging of the breast in a configuration similar to many clinical applications including ultrasound and breast conserving surgeries. This would facilitate the image registration of MR images for aid of these applications. However, standard Cartesian sampling has non-isotropic spatial resolution, which is undesirable when the registered images are presen...

متن کامل

3D Undersampled Golden-Radial Phase Encoding Using Iterative Reconstructions and Inherent Regularization

INTRODUCTION: The reconstruction of sensitivity–encoded non–Cartesian undersampled MRI has been facilitated by the use of iterative techniques [1]. However, the ill-conditioning of the associated inverse problem produces residual aliasing and noise amplification. A proven approach to stabilize the reconstruction and to diminish these effects is the use of explicit regularization methods [2-3], ...

متن کامل

Improving Fat Suppression in Radial Coronary Mra Using a Weighted Golden Ratio Acquisition

INTRODUCTION: Coronary MR angiography benefits from the favorable motion properties of radial k-space sampling [1-2], which allow reducing scan time by use of longer cardiac acquisition windows [3]. However, recovery of epicardial fat signal during the prolonged data acquisition window may impair image quality as radial trajectories repeatedly sample the center of k-space. Moreover, the effecti...

متن کامل

Single session whole body T2-weighted and T1-weighted MRI (both with and without fat suppression)

Introduction: An MRI study is commonly used for examining the local extent of a disease and often consists of acquiring images of the same region with different image contrasts. Using a moving tabletop and without re-positioning the patient, MRI has also been shown to be a feasible tool for whole body screening or staging of a disease [1-3]. In this regard, whole body MRI is potentially more ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008