Nationwide Multicenter Reference Interval Study for 28 Common Biochemical Analytes in China.

نویسندگان

  • Liangyu Xia
  • Ming Chen
  • Min Liu
  • Zhihua Tao
  • Shijun Li
  • Liang Wang
  • Xinqi Cheng
  • Xuzhen Qin
  • Jianhua Han
  • Pengchang Li
  • Li'an Hou
  • Songlin Yu
  • Kiyoshi Ichihara
  • Ling Qiu
چکیده

A nationwide multicenter study was conducted in the China to explore sources of variation of reference values and establish reference intervals for 28 common biochemical analytes, as a part of the International Federation of Clinical Chemistry and Laboratory Medicine, Committee on Reference Intervals and Decision Limits (IFCC/C-RIDL) global study on reference values. A total of 3148 apparently healthy volunteers were recruited in 6 cities covering a wide area in China. Blood samples were tested in 2 central laboratories using Beckman Coulter AU5800 chemistry analyzers. Certified reference materials and value-assigned serum panel were used for standardization of test results. Multiple regression analysis was performed to explore sources of variation. Need for partition of reference intervals was evaluated based on 3-level nested ANOVA. After secondary exclusion using the latent abnormal values exclusion method, reference intervals were derived by a parametric method using the modified Box-Cox formula. Test results of 20 analytes were made traceable to reference measurement procedures. By the ANOVA, significant sex-related and age-related differences were observed in 12 and 12 analytes, respectively. A small regional difference was observed in the results for albumin, glucose, and sodium. Multiple regression analysis revealed BMI-related changes in results of 9 analytes for man and 6 for woman. Reference intervals of 28 analytes were computed with 17 analytes partitioned by sex and/or age. In conclusion, reference intervals of 28 common chemistry analytes applicable to Chinese Han population were established by use of the latest methodology. Reference intervals of 20 analytes traceable to reference measurement procedures can be used as common reference intervals, whereas others can be used as the assay system-specific reference intervals in China.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A multicenter nationwide reference intervals study for common biochemical analytes in Turkey using Abbott analyzers.

BACKGROUND A nationwide multicenter study was organized to establish reference intervals (RIs) in the Turkish population for 25 commonly tested biochemical analytes and to explore sources of variation in reference values, including regionality. METHODS Blood samples were collected nationwide in 28 laboratories from the seven regions (≥400 samples/region, 3066 in all). The sera were collective...

متن کامل

A reference interval study for common biochemical analytes in Eastern Turkey: a comparison of a reference population with laboratory data mining

INTRODUCTION The aim of this study was to define the reference intervals (RIs) in a Turkish population living in Northeast Turkey (Erzurum) for 34 analytes using direct and indirect methods. In the present study, the regional RIs obtained were compared with other RI studies, primarily the nationwide study performed in Turkey. MATERIALS AND METHODS For the direct method, 435 blood samples were...

متن کامل

First Definition of Reference Intervals of Liver Function Tests in China: A Large-Population-Based Multi-Center Study about Healthy Adults

BACKGROUND Reference intervals of Liver function tests are very important for the screening, diagnosis, treatment, and monitoring of liver diseases. We aim to establish common reference intervals of liver function tests specifically for the Chinese adult population. METHODS A total of 3210 individuals (20-79 years) were enrolled in six representative geographical regions in China. Analytes of...

متن کامل

Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?

Background: Clinical application of the test results are profoundly influenced by laboratory errors. Nowadays, the best way to evaluate the performance of a method is to determine its sigma scale according to total allowable error (TEa) and analytical errors, including random and systematic errors. In this study, the performance of the measuring kits for biochemical analytes belonging to Pars A...

متن کامل

A Multicenter Reference Intervals Study for Specific Proteins in China

A multicenter study conducted in healthy population of 6 cities from the 4 corners and central China for 7 serum-specific proteins to identify the sources of variation and establish the reference intervals on 2 automation platforms.A total of 3148 subjects aged 19 to 64 years old were enrolled in this study to ensure at least 120 participants in each 10-year age group and each city. The majorit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine

دوره 95 9  شماره 

صفحات  -

تاریخ انتشار 2016