[18F]Ciprofloxacin, a new positron emission tomography tracer for noninvasive assessment of the tissue distribution and pharmacokinetics of ciprofloxacin in humans.

نویسندگان

  • Martin Brunner
  • Oliver Langer
  • Georg Dobrozemsky
  • Ulrich Müller
  • Markus Zeitlinger
  • Markus Mitterhauser
  • Wolfgang Wadsak
  • Robert Dudczak
  • Kurt Kletter
  • Markus Müller
چکیده

The biodistribution and pharmacokinetics of the fluorine-18-labeled fluoroquinolone antibiotic [(18)F]ciprofloxacin in tissue were studied noninvasively in humans by means of positron emission tomography (PET). Special attention was paid to characterizing the distribution of [(18)F]ciprofloxacin to select target tissues. Healthy volunteers (n = 12) were orally pretreated for 5 days with therapeutic doses of unlabeled ciprofloxacin. On day 6, subjects received a tracer dose (mean injected amount, 700 +/- 55 MBq, which contained about 0.6 mg of unlabeled ciprofloxacin) of [(18)F]ciprofloxacin as an intravenous bolus. Thereafter, PET imaging and venous blood sampling were initiated. Time-radioactivity curves were measured for liver, kidney, lung, heart, spleen, skeletal muscle, and brain tissues for up to 6 h after radiotracer administration. The first application of [(18)F]ciprofloxacin in humans has demonstrated the safety and utility of the newly developed radiotracer for pharmacokinetic PET imaging of the tissue ciprofloxacin distribution. Two different tissue compartments of radiotracer distribution could be identified. The first compartment including the kidney, heart, and spleen, from which the radiotracer was washed out relatively quickly (half-lives [t(1/2)s], 68, 57, and 106 min, respectively). The second compartment comprised liver, muscle, and lung tissue, which displayed prolonged radiotracer retention (t(1/2), >130 min). The highest concentrations of radioactivity were measured in the liver and kidney, the main organs of excretion (standardized uptake values [SUVs], 4.9 +/- 1.0 and 9.9 +/- 4.4, respectively). The brain radioactivity concentrations were very low (<1 kBq. g(-1)) and could therefore not be quantified. Transformation of SUVs into absolute concentrations (in micrograms per milliliter) allowed us to relate the concentrations at the target site to the susceptibilities of bacterial pathogens. In this way, the frequent use of ciprofloxacin for the treatment of a variety of infections could be corroborated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 2004