Temperature elevation after vertebroplasty with polymethyl-methacrylate in the goat spine.

نویسندگان

  • Jorrit-Jan Verlaan
  • F Cumhur Oner
  • Abraham J Verbout
  • Wouter J A Dhert
چکیده

Although the general complication rate for vertebroplasty is low, neural compression and thermal damage have been related to the use of polymethyl-methacrylate cement. This study focuses on the risk of thermal tissue damage after vertebroplasty. In this study, cavities were created by a transpedicular approach in the vertebral bodies (L3, L4, and L5) of four milk goats, and polymethyl-methacrylate cement was injected. In three locations (the bone-cement interface, the epidural space, and the disc space) the temperature was measured in regular intervals after injection of the cement. The mean injected volume was 0.8 ml, which accounted for a 22% volume fraction. The mean peak temperature of the bone-cement interface was 44.6 degrees C, while the maximum temperature at the epidural space and disc space was 37.0 and 37.5 degrees C, respectively. The local temperature measured after in vivo vertebroplasty did not reach values that are known to cause tissue necrosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT guided direct transoral approach to C2 for percutaneous vertebroplasty.

BACKGROUND Percutaneous vertebroplasty is a well-established procedure consisting of the percutaneous injection of a biomaterial, usually Polymethyl methacrylate (PMMA), into a vertebral body. In most cases, this procedure affords significant pain relief and strengthens the bone. Vertebroplasty is most typically performed successfully with patients with acute compression fractures. OBJECTIVE ...

متن کامل

Fatal fat embolism after vertebroplasty: identification of the high-risk patient.

We report a rare complication of autopsy-proven fat and bone marrow embolization following percutaneous vertebroplasty in a patient who had no evidence of cement leakage. Cement injection was done during one patient encounter, covering 3 vertebral levels by using a unipedicular approach. Patients may have complications even without polymethylmethacrylate leakage.

متن کامل

Surgical Removal of Circumferentially Leaked Polymethyl Methacrylate in the Epidural Space of the Thoracic Spine after Percutaneous Vertebroplasty.

Background  The major complication of percutaneous vertebroplasty (PVP) using polymethyl methacrylate (PMMA) is epidural leakage of PMMA that damages the spinal cord. Methods  This is a case report. Result  A 77-year-old man presented to our institution with a 6-month history of muscle weakness and an intolerable burning sensation of both lower limbs after PVP with PMMA for thoracic compression...

متن کامل

A Classification System for the Spread of Polymethyl Methacrylate in Vertebral Bodies Treated with Vertebral Augmentation

In this study, we develop a classification system for describing polymethyl methacrylate (PMMA) spread in vertebral bodies after kyphoplasty or vertebroplasty for vertebral compression fractures (VCFs) and for assessing whether PMMA spread varies between operators, VCF etiology, or vertebral level. Intraoperative fluoroscopic images of 198 vertebral levels were reviewed in 137 patients (women, ...

متن کامل

Effects of cement augmentation on the mechanical stability of multilevel spine after vertebral compression fracture.

BACKGROUND Studies on the effects of cement augmentation or vertebroplasty on multi-level spine after vertebral compression fractures are lacking. This paper seeks to establish a 3-vertebrae ovine model to determine the impact of compression fracture on spine biomechanics, and to discover if cement augmentation can restore mechanical stability to fractured spine. METHODS Five lumbar spine seg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 2003