Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurements.
نویسندگان
چکیده
AIMS To evaluate the test-retest variability of stereometric parameter measurements made with the Heidelberg retina tomograph (HRT) and Heidelberg retina tomograph-II (HRT-II), and to establish which parameter(s) provided the most repeatable and reliable measurements with both devices. An investigation into the factors affecting the repeatability of the measurements of this parameter(s) was conducted. METHODS 43 ocular hypertensive and 31 glaucoma subjects were recruited to a test-retest study. One eye from each subject underwent HRT and HRT-II imaging by two observers on each of two occasions within 6 weeks of each other. Lens grading was carried out by LOCS III grading and Scheimpflug camera generated densitogram analysis. RESULTS Rim area (RA) and mean cup depth measurements were found to be least variable. Both inter-test reference height difference and image quality had a strong relation (R(2)>0.5, p<0.0001) with inter-test RA difference and, together, are responsible for 70% of RA measurement variability. Image quality was influenced by lens opacity, cylindrical error, and age. Inter-test RA measurement differences were unrelated to the observer or visit interval. CONCLUSIONS RA represents an appropriate measure for monitoring glaucomatous progression. Reference height difference and image quality were the factors that most influenced RA measurement variability. Image analysis strategies that address these factors may reduce test-retest variability.
منابع مشابه
Factors affecting the variability of the Heidelberg Retina Tomograph III measurements in newly diagnosed glaucoma patients.
PURPOSE To determine factors associated with the test-retest variability of optic nerve head (ONH) topography measurements with confocal scanning laser ophthalmoscopy (CSLO) in newly diagnosed glaucomatous patients. METHODS Consecutive patients with newly diagnosed primary open-angle glaucoma were prospectively enrolled. Patients presenting with any ocular disease other than glaucoma were exc...
متن کاملSCIENTIFIC REPORT Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements
Aims: To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. Methods: The effect of the standard and 320 mm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image dataset fr...
متن کاملImproving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements.
AIMS To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. METHODS The effect of the standard and 320 microm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image datase...
متن کاملComparison of Neuroretinal Rim Area Measurements Made by the Heidelberg Retina Tomograph I and the Heidelberg Retina Tomograph II
PURPOSE To investigate the agreement between neuroretinal rim area (RA) measurements using the Heidelberg Retina Tomograph I (HRT Classic) and Heidelberg Retina Tomograph II (HRT II). To compare apparent RA changes in follow-up series of HRT II topographies when using either an HRT Classic or HRT II mean topography as baseline. DESIGN Cross-sectional study and "no-change," short time series s...
متن کاملDevelopment and evaluation of a contrast sensitivity perimetry test for patients with glaucoma.
PURPOSE To design a contrast sensitivity perimetry (CSP) protocol that decreases variability in glaucomatous defects while maintaining good sensitivity to glaucomatous loss. METHODS Twenty patients with glaucoma and 20 control subjects were tested with a CSP protocol implemented on a monitor-based testing station. In the protocol 26 locations were tested over the central visual field with Gab...