Safety Testing of Left Ventricular Vent Valves.

نویسندگان

  • Caroline Gavin
  • John Coblentz
  • Jeffrey R Acsell
  • Anthony G Shackelford
  • Joseph J Sistino
چکیده

Vent vacuum relief valves (VRVs) are used to limit the negative pressure at the ventricular vent catheter tip as well as prevent reversal of blood flow and prevention of air embolism. The purpose of this study was to evaluate the performance of three commercially available ventricular vent valves. The negative pressure at which the vent valve opened was measured at the valve inlet using high-fidelity pressure transducers. Also, the flow rate at which air entrainment occurred due to valve opening was recorded. Using a 51.5 cm column of saline, the resistance for each valve was calculated. The mean ± SD opening negative pressures were -231.3 ± 35.2 mmHg for the Quest Medical valve, -219.8 mmHg ± 17.2 for the Sorin valve, and -329.6 · 38.0 mmHg for the Terumo valve. The red Quest Medical valve opened at a lower flow (1.44 ± .03 L/min) than the dark blue Sorin valve (2.93 ± .01 L/min) and light blue LH130 Terumo valve (2.36 ± .02 L/min). The Sorin valve had the least resistance of 34.1 dyn-s/cm, followed by the Terumo LH130 valve resistance of 58.1 dyn·s/cm5, and the Quest Medical VRV-II valve with a resistance of 66.5 dyn·s/cm. We found that the valves are significantly different in the negative pressure generated. Understanding the limitations of these devices is important to reduce the occurrence of adverse events associated with venting and to select the best device for a specific clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro comparison tests of three LV vent valves.

Many surgical teams employ a sump pump to vent the left ventricle (LV). The problems associated with this technique are related to safety and convenience. If the flow is accidentally reversed in the LV vent line, air embolism accidents and subsequent litigation may be the result. If the cannula is occluded, it is inconvenient to juggle pump speed to prevent the line from collapsing while mainta...

متن کامل

Short-term performance of mitral valve replacement with porcine bioprosthetic valves in dogs.

Porcine bioprosthetic valves cross-linked with glutaraldehyde and polyepoxy compound were newly developed for mitral valve replacement (MVR) in dogs. Five beagle dogs were performed a left thoracotomy and underwent MVR using the porcine bioprosthetic valves during cardiopulmonary bypass (CPB). A vein catheter inserted into right atrium and a vent catheter inserted into the right ventricle to dr...

متن کامل

Extracorporeal life support with left ventricular decompression—improved survival in severe cardiogenic shock: results from a retrospective study

OBJECTIVE Extracorporeal life support (ECLS) is a life-saving procedure used in the treatment of severe cardiogenic shock. Within this retrospective single centre study, we examined our experience in this critically ill patient cohort to assess outcomes and clinical parameters by comparison of ECLS with or without selective left ventricular decompression. METHODS Between 2004 and 2014 we eval...

متن کامل

Experimental Validation of a Cardiac Simulator for in vitro Evaluation of Prosthetic Heart Valves

OBJECTIVE This work describes the experimental validation of a cardiac simulator for three heart rates (60, 80 and 100 beats per minute), under physiological conditions, as a suitable environment for prosthetic heart valves testing in the mitral or aortic position. METHODS In the experiment, an aortic bileaflet mechanical valve and a mitral bioprosthesis were employed in the left ventricular ...

متن کامل

Refuge alternatives relief valve testing and design.

The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2015