Control Parameter Selection in Auxiliary Resonant Commutated Pole Converters
نویسنده
چکیده
This paper addresses the optimum selection of the boost current and threshold current control parameters for the ARCP soft switching technique. The parameters are derived based on a minimization of the output voltage distortion induced by the ARCP operation. The impact of the proper selection of the resonant parameters on the system design is discussed.
منابع مشابه
A. a Novel Two-quadrant Soft-switching Converter with One Auxiliary Switch for High Power Applications
There has been an increasing interest in the soft-switching power conversion technologies in order to overcome the limitations of the hard-switching technologies [1]-[7]. Soft-switching (SS) converters had many advantages over hard-switching (HS) converters. For example, SS converters lower switching losses, reduce voltage/current stress, reduce EMI, and allow a greater high switching frequency...
متن کاملPerformance Characteristics and Average-Value Modeling of Auxi
The auxiliary resonant commutated pole (ARCP) converter is currently of intense interest for use in a variety of power electronic converters, and is one of the cornerstones of the Navy's Power Electronic Building Block (PEBB) effort. In this paper a detailed discussion of the required switching times needed to achieve completely soft switching operation with only one current sensor per phase is...
متن کاملInvestigation of Novel Transformerless Converters for DC Microgrid: Design and Analysis
This paper proposes two new soft-switching transformerless converters with high voltage conversion ratio. These proposed converters achieve soft-switching each with a single auxiliary resonant cell. The merit of these converters is reduced switching losses with lesser number of devices. The main switching devices are turned off with zero current switching (ZCS). Apart from the soft-switching fe...
متن کاملAbstract – In this paper, the unedited race-control algorithm (RCA) for the full-bridge passive resonant commutated poles (FB-PRCP) converter is presented and implemented in cost effective field programmable gate-array
In this paper, the unedited race-control algorithm (RCA) for the full-bridge passive resonant commutated poles (FB-PRCP) converter is presented and implemented in cost effective field programmable gate-array. It compensates the drawbacks of that topology that are related to the slow dynamics of the auxiliary poles which are necessary to obtain zero-voltage transitions both at turn-on and turn-o...
متن کاملA New ZVZCS Isolated Dual Series Resonant DC-DC Converter with EMC Considerations
A novel ZVZCS isolated dual series-resonant active-clamp dc–dc converter is proposed to obtain high efficiency. The proposed converter employs an active-clamp technique, while a series-resonant scheme controls the output voltage with the complementary pulse width modulation controller. The active-clamp circuit serves to recycle the energy stored in the leakage inductance or the magnetizing ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -