Rapid MR Imaging with "Compressed Sensing" and Randomly Under-Sampled 3DFT Trajectories
نویسندگان
چکیده
M. Lustig, D. L. Donoho, J. M. Pauly Electrical Engineering, Stanford University, Stanford, CA, United States, Statistics, Stanford University, Stanford, CA, United States Introduction Recently a rapid imaging method was proposed [1] that exploits the fact that sparse or compressible signals, such as MR images, can be recovered from randomly under-sampled frequency data [1,2,3]. Because pure random sampling in 2D is impractical for MRI hardware, it was proposed to use randomly perturbed spirals to approximate random sampling. Indeed, pure 2D random sampling is impractical, however, randomly undersampling the phase encodes in a 3D Cartesian scan (Fig. 1) is practical, involves no overhead, is simple to implement and is purely random in two dimensions. Moreover, scan-time reduction in 3D Cartesian scans is always an issue. We provide a method to evaluate the effective randomness of a randomly under-sampled trajectory by analyzing the statistics of aliasing in the sparse transform domain. Applying this method to MR angiography, where images are truly sparse, we demonstrate a 5fold scan time reduction, which can be crucial in time-limited situations or can be used for time resolved imaging Theory Medical images in general, and specifically angiograms, often have a sparse representation using a linear transform (wavelets, DCT, finite differences, etc.)[1]. Under-sampling the Fourier domain results in aliasing. When the under-sampling is random, the aliasing is incoherent and acts as additional noise interference in the image, but more importantly, as incoherent interference of the sparse transform coefficients. Therefore, it is possible to recover the sparse transform coefficients using a non-linear reconstruction scheme [1-4] and consequently, recover the image itself. The interference in the sparse domain is a generalization of a point-spread function (PSF) and is computed by I(n,m)= where xn is the n th
منابع مشابه
Rapid Imaging using Undersampled Radial Trajectories and L1 Reconstruction
Introduction: Compressed Sensing (CS) is an emerging field that suggests that data compression can be implicitly incorporated into the data acquisition process [1,2,3]. CS is regarded by some as an alternative to Shannon’s Nyquist sampling theory. The Nyquist sampling theory states that the number of samples required to perfectly reconstruct a signal is determined by its bandwidth. In contrast,...
متن کاملInterleaved Variable Density Sampling with ARC Parallel Imaging and Cartesian HYPR for Dynamic MR Angiography
INTRODUCTION For MR applications such as contrast-enhanced MR angiography (CE-MRA), it is desirable to simultaneously achieve high spatial and temporal resolutions; however fully-sampled Cartesian acquisition of large matrices is time consuming. View sharing combined with parallel imaging (PI) improves temporal resolution [1], as does incoherent under-sampling with compressed sensing (CS) [2] o...
متن کاملHigh resolution projection reconstruction MR imaging using FOCUSS
This paper is concerned about high resolution reconstruction of projection reconstruction MR imaging from angular under-sampled k-space data. A similar problem has been recently addressed in the framework of compressed sensing theory. Unlike the existing algorithms used in compressed sensing theory, this paper employs the FOCal Underdetermined System Solver(FOCUSS), which was originally designe...
متن کاملApplication of “Compressed Sensing” for Rapid MR Imaging
Introduction In a typical magnetic resonance imaging (MRI) experiment, samples are collected in the so-called k-space or frequency domain of the image. The number of samples needed for reconstruction at a given resolution and field of view is normally set by the Nyquist criteria and occupies a certain amount of bits in memory. However, it is commonly known that if we take the reconstructed imag...
متن کاملCompressed Sensing for Motion Artifact Reduction
Introduction: Navigators can effectively track rigid-body motion of limited amplitude, such as respiratory motion [1,2,3]. In a Cartesian scan, data is corrected by applying to each k-space line the phase modulation corresponding to the amount of detected motion. However, lines associated with significant motion (e.g., swallowing in larynx imaging) are uncorrectable and therefore need to be dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005