This manuscript analyzes the dynamics of coalescence of an incoming aqueous plug with a wetting layer above a hydrophilic surface in the chemistrode. The chemistrode is a recently described (Chen, D.; Du, W.; Liu, Y.; Liu, W.; Kuznetsov, A.; Mendez, F. E.; Philipson, L. H.; Ismagilov, R. F. Proc. Natl. Acad. Sci. U.S.A. 2008, 105, 16843-16848) microfluidic analogue of an electrode, but operating at the chemical rather than electrical level, developed with the aim of capturing local stimulus-response processes in chemistry and biology. The chemistrode consists of open-ended V-shaped microfluidic channels that can be brought into contact with a chemical or biological hydrophilic substrate. The chemistrode relies on multiphase aqueous/fluorous flow and uses plugs to achieve high temporal resolution of stimulation and sampling. Coalescence of the incoming plugs, containing the stimuli, with the liquid in the wetting layer is required for chemical exchange to take place in the chemistrode. Here, we investigate the system with triethyleneglycol mono[1H,1H-perfluorooctyl]ether RfOEG as the surfactant. This surfactant was necessary to prevent nonspecific absorption of proteins to the aqueous fluorous interface and to ensure biocompatibility of the system, but too much surfactant increased the barrier for coalescence. In this system, coalescence was controlled by the capillary number. At a higher value of the capillary number, coalescence took more time, and deformation of the interface of the incoming plug and the wetting layer was more significant. Above a critical capillary number, coalescence did not occur between the incoming plug and the wetting layer. The critical capillary number was an increasing function of surface tension but was independent of viscosity ratio. Coalescence was surprisingly reproducible, presumably because film rupture during coalescence was reliably initiated at the hydrophilic substrate. These results are useful in rational operation of the chemistrode and also provide an experimental description of deformation, film drainage, and coalescence of surfactant-coated droplets in an external flow field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using TIRF microscopy to quantify and confirm efficient mass transfer at the substrate surface of the chemistrode.

This paper describes experiments for characterizing mass transfer at the hydrophilic surface of the substrate in a chemistrode. The chemistrode uses microfluidic plugs to deliver pulses of chemicals to a substrate with high temporal resolution, which requires efficient mass transfer between the wetting layer and the hydrophilic surface of the substrate. Here, total internal reflection fluoresce...

متن کامل

Using three-phase flow of immiscible liquids to prevent coalescence of droplets in microfluidic channels: criteria to identify the third liquid and validation with protein crystallization.

This manuscript describes the effect of interfacial tensions on three-phase liquid-liquid-liquid flow in microfluidic channels and the use of this flow to prevent microfluidic plugs from coalescing. One problem in using microfluidic plugs as microreactors is the coalescence of adjacent plugs caused by the relative motion of plugs during flow. Here, coalescence of reagent plugs was eliminated by...

متن کامل

Surface-directed boundary flow in microfluidic channels.

Channel geometry combined with surface chemistry enables a stable liquid boundary flow to be attained along the surfaces of a 12 microm diameter hydrophilic glass fiber in a closed semi-elliptical channel. Surface free energies and triangular corners formed by PDMS/glass fiber or OTS/glass fiber surfaces are shown to be responsible for the experimentally observed wetting phenomena and formation...

متن کامل

Numerical Study of Droplet Generation Process in a Microfluidic Flow Focusing

Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...

متن کامل

Isolation, incubation, and parallel functional testing and identification by FISH of rare microbial single-copy cells from multi-species mixtures using the combination of chemistrode and stochastic confinement.

This paper illustrates a plug-based microfluidic approach combining the technique of the chemistrode and the principle of stochastic confinement, which can be used to i) starting from a mixture of cells, stochastically isolate single cells into plugs, ii) incubate the plugs to grow clones of the individual cells without competition among different clones, iii) split the plugs into arrays of ide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Langmuir : the ACS journal of surfaces and colloids

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 2009