Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique *,**
نویسندگان
چکیده
OBJECTIVE To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH₂O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH₂O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/ PEF ratio was attributable to overly rapid inflations and low VT.
منابع مشابه
Bronchial hygiene technique with manual hyperinflation and thoracic compression: effectiveness and safety.
OBJECTIVES To evaluate the effects of the manual hyperinflation with thoracic compression (MHTC) maneuver on the clearance of secretions, pulmonary mechanics, hemodynamics and oxygenation in mechanically ventilated patients. METHODS This was a controlled, crossover study that included twenty patients who were under invasive ventilation for more than 48 hours. Four hours after the last airway ...
متن کاملEffect of Lung Manual Hyperinflation (MHI) on Oxygenation of Patients Following Abdominal Surgery and T-Tube Support
Background: Postoperative pulmonary complications (PPC) are of the major reasons for death. Prolonged mechanical ventilation (PMV) and delayed extubation are leading to the incidence of more seriously complications. The effect of hyperinflation has not been investigated in control of these complications in patients who have been weaned from mechanical ventilation and are undergoing T-tube suppo...
متن کاملPattern of ventilation during manual hyperinflation performed by physiotherapists.
Summary The aim of this prospective observational study was to document patterns of ventilation during manual hyperinflation by physiotherapists. Manual hyperinflation with a Mapleson-F system was performed on the same patients on two consecutive days. Patterns of ventilation were recorded using a heated pneumotachometer, pressure transducer and custom designed data acquisition and analysis sys...
متن کاملThe use of manual hyperinflation in airway clearance.
Manual lung hyperinflation (MH) is one of a number of techniques which are employed by the physiotherapist in the critical care setting. The technique was first described with physiotherapy 30 yrs ago and commonly involves a slow, deep inspiration, inspiratory pause and fast unobstructed expiration. The use of MH varies between and within countries. It is commonly employed by physiotherapists t...
متن کاملEvaluation of the Safety and Effectiveness of the Rapid Flow Expulsion Maneuver to Clear Subglottic Secretions in Vitro and in Vivo.
BACKGROUND Clearing subglottic secretions has been proved to reduce ventilator-associated pneumonia. A manual method named the rapid flow expulsion maneuver was developed to clear subglottic secretions. This study evaluates its safety and effectiveness and analyzes the influential factors. METHODS This study was composed of 2 parts. In an in vitro study, secretions were instilled directly to ...