Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging.
نویسندگان
چکیده
Cine magnetic resonance imaging (MRI) is a gradient-recalled, retrospectively gated, fast-scan technique that depicts laminar flowing blood as bright signal and has been proposed as a useful method for determination of coronary artery bypass graft (CABG) patency. Therefore, we performed a blinded prospective study to assess the value of cine MRI determination of CABG patency in 20 patients with 45 CABG proximal anastomoses who were undergoing repeat angiography. Ten normal subjects served as controls to define normal intrathoracic vascular patterns. There were 21 left anterior descending (LAD) grafts, of which four were left internal mammary (LIMA), 12 left circumflex (Cx), and 12 right coronary (RCA) grafts. After localizing spin-echo coronal images were obtained, multiple axial multislice interleaved cine MRI acquisitions, each consisting of two to four 5-10-mm-thick slices at eight to 24 frames per cardiac cycle, were obtained from the superior main pulmonary artery to the inferior left ventricle. Each acquisition took 5-8 minutes with a subsequent 5-10 minutes of computer image reconstruction. Total study time per patient was 50-75 minutes. Known to cine MRI interpreters were the original surgical CABG insertions but not the angiographic findings. A graft was called patent if a bright graft flow signal, not corresponding to a normal vessel, was identified on multiple frames at multiple levels abutting the great vessels or epicardial surface of the heart. Angiographically, there were 33 patent grafts, of which 29 were identified as patent by cine MRI (sensitivity, 88%).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Comprehensive assessment of a post-coronary bypass graft patient with cardiovascular magnetic resonance imaging and multi-detector computed tomography
Coronary bypass graft surgery (CABG) is a revascularization procedure which reduces myocardial ischemia and cardiovascular morbidity and mortality in selected patients; however, up to 40% of saphanous vein grafts may degenerate over 10 years. Although coronary angiography is the gold standard to detect graft patency and native vessel disease, sometimes it is difficult to locate the grafts resul...
متن کاملNoninvasive postoperative angiography for internal mammary artery grafts.
Recently, noninvasive imaging modalities such as electron-beam computed tomography, magnetic resonance angiography, and single-slice helical computed tomography (CT) have emerged as ways to visualize the coronary arteries. With regard to internal mammary artery grafts, however, conventional 3D imaging techniques have failed to demonstrate consistently satisfactory performance. We overcame these...
متن کاملIs there an indication for computed tomography and magnetic resonance imaging in the evaluation of coronary artery bypass grafts?
This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive imaging in post-coronary artery bypass graft patients with these techniques is discussed. Overall, M...
متن کاملProspective evaluation of ultrafast cardiac computed tomography for determination of coronary bypass graft patency.
Twenty-five consecutive patients with 68 independent (single distal anastomosis) saphenous vein aortocoronary and 12 internal mammary bypass grafts (27 to left anterior descending, 10 to diagonal, 23 to left circumflex, 20 to right coronary artery) entered a reader-blinded, prospective, standardized study to establish the accuracy of ultrafast (cine) cardiac computed tomography (CT) for determi...
متن کاملCine computed tomographic evaluation of aortocoronary bypass graft patency.
Evaluation of the patency of coronary bypass grafts has previously required hospitalization for invasive angiography. This report of three cases documents the unique capability of cardiac cine computed tomography to easily and accurately define coronary bypass graft patency. In each case, the findings altered therapeutic decisions. This early experience justifies wider application of this techn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 80 6 شماره
صفحات -
تاریخ انتشار 1989