Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs.

نویسندگان

  • R W Nyffeler
  • C Anglin
  • R Sheikh
  • C Gerber
چکیده

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantle were studied in human glenoid bone. The lowest pull-out forces, 20 +/- 5 N, were for cylindrical pegs with a smooth surface fixed in the glenoid with a thin cement mantle. The highest values, 425 +/- 7 N, were for threaded pegs fixed with a thicker cement mantle. Increasing the diameter of the hole into which the peg is inserted from 5.2 to 6.2 mm thereby increasing the thickness of the cement mantle, improved the mean pull-out force for the pegs tested.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of peg designs on glenoid component: A finite element study

Glenoid loosening was associated with stress at the implant and cement. The purpose of this study was to determine the effect of pegs and its distribution on stress transfer to the implant and cement. Six commercially available implant designs were simulated via finite element analysis with different peg distributions. Maximum stress at the implant and cement and stress critical area (SCA) at t...

متن کامل

Total Shoulder Arthroplasty Biomechanical Testing of the Fixation of a New Glenoid Design

The Comprehensive® Shoulder Solutions’ Modular Hybrid Glenoid from Biomet is a revolutionary design for replacement of the glenoid in total shoulder arthroplasty. It provides three outer pegs and three central peg options for surgical implantation. In vitro testing of the Modular Hybrid Glenoid resulted in mean axial pull-out peak loads ranging from 209 to 303 lbf, mean inferior/superior shear ...

متن کامل

Biomechanical Evaluation of All-Polyethylene Pegged Bony Ingrowth Glenoid Fixation Techniques on Implant Micromotion.

Newer glenoid components that allow for hybrid cement fixation via traditional cementation of peripheral pegs and bony ingrowth into an interference-fit central peg introduce the possibility of long-term biological fixation. However, little biomechanical work has been done on the initial stability of these components and the various fixation options. We conducted a study in which all-polyethyle...

متن کامل

Total Shoulder Arthroplasty

The Comprehensive® Shoulder Solutions’ Modular Hybrid Glenoid from Biomet is a revolutionary design for replacement of the glenoid in total shoulder arthroplasty. It provides three outer pegs and three central peg options for surgical implantation. In vitro testing of the Modular Hybrid Glenoid resulted in mean axial pull-out peak loads ranging from 209 to 303 lbf, mean inferior/superior shear ...

متن کامل

Glenoid perforation with pegged components during total shoulder arthroplasty.

A subset of patients undergoing primary total shoulder arthroplasty (TSA) have a medialized joint line secondary to glenoid wear. In some cases, the central pegs or peripheral pegs of a peg design glenoid component may violate the medial cortex of the glenoid vault. It is unknown whether this leads to early failure. The objectives of this study were to determine (1) whether glenoid components w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 85 5  شماره 

صفحات  -

تاریخ انتشار 2003