Prospective acquisition correction for head motion with image-based tracking for real-time fMRI.
نویسندگان
چکیده
In functional magnetic resonance imaging (fMRI) head motion can corrupt the signal changes induced by brain activation. This paper describes a novel technique called Prospective Acquisition CorrEction (PACE) for reducing motion-induced effects on magnetization history. Full three-dimensional rigid body estimation of head movement is obtained by image-based motion detection to a high level of accuracy. Adjustment of slice position and orientation, as well as regridding of residual volume to volume motion, is performed in real-time during data acquisition. Phantom experiments demonstrate a high level of consistency (translation < 40 microm; rotation < 0.05 degrees ) for detected motion parameters. In vivo experiments were carried out and they showed a significant decrease of variance between successively acquired datasets compared to retrospective correction algorithms.
منابع مشابه
Hybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors
INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based na...
متن کاملReal-Time Prospective Slice-by-Slice Motion Correction for fMRI in Freely Moving Subjects
INTRODUCTION Functional Magnetic Resonance Imaging (fMRI) is being used extensively in neuroscientific studies and is entering the clinical field. Due to its low inherent effect to noise ratio even at high field strength the results are often compromised by adverse events during the acquisition. The most frequent cause of signal fluctuations that degrade the detection of paradigm induced neuron...
متن کاملProspective motion correction of 3D echo-planar imaging data for functional MRI using optical tracking
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and ...
متن کاملReal-Time Intra-Volume Motion Correction in EPI Using Active Markers
Introduction: Echo-planar imaging (EPI) is the sequence of choice for functional MRI (fMRI), where rapid scanning is needed in order to continuously acquire complete brain volumes for a time-series analysis. Even a few millimeters of movement during an fMRI scan can result in large, artifactual, signal changes in the timeseries data that will obscure the relatively small brain activation signal...
متن کاملHead pose prediction for prospectively-corrected EPI during rapid subject motion
INTRODUCTION Prospective motion correction using an external tracking device is an effective technique for motion correction in fMRI [1]. It has advantages over image-based correction methods [2], which require full volume coverage to compute motion parameters in a full six degrees of freedom (6DOF). The ultimate goal of this project is to use prospective correction to perform fMRI experiments ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2000