3-D Multi-Coil Motion Correction for Spiral Projection Imaging

نویسندگان

  • K. O. Johnson
  • E. Aboussouan
چکیده

Introduction Patient motion is a significant problem for MR imaging. Spiral Projection Imaging (SPI) is a 3-D imaging sequence, which provides enough data to deduce all six degrees of freedom of bulk motion [1]. Motion correction has been successfully demonstrated for quadrature coil data (both real and synthetic), by comparing data from individual planes [2,3] (Fig. 1). The extension to multi-coil data is complicated by the introduction of receiver coil sensitivity and phase. This work presents an appropriate approximation by combining multi-coil data in order to facilitate motion correction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MOtion Correction using Coil Arrays (MOCCA)

Introduction: Robust motion correction is challenging in many MRI applications. Over the past two decades, several approaches have been proposed to suppress cardiac, respiratory or bulk motion [1-5]. We present a novel MOtion Correction method using Coil Arrays (MOCCA) that can be used for various motion corrections. In MOCCA, the elements of a coil array are used as individual motion “sensors”...

متن کامل

Compensation of Abdominal Breathing Artifacts in Multi-Shot Acquisitions Using Parallel Imaging and Automatic Coil Weight Selection from Adjacent Slices

Introduction Breathing motion during multi-shot acquisitions causes artifacts which appear as ghosts in the reconstructed images. Various techniques for motion correction using parallel imaging have been proposed [1-5]. They reconstruct images from subdivisions of motion corrupted k-space data and average them subsequently for artifact reduction [2], replace motion corrupted k-space lines [3] o...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Retrospective estimation of 3D respiratory motion vectors in coronary MRI

Introduction: Diaphragm navigator gating and tracking is an accepted technique for respiratory motion-compensation in free-breathing cardiac MR. Navigator tracking was developed in an effort to increase the gating window and hence navigator efficiency. It is typically performed using a fixed tracking factor of 0.6 for all patients [1, 2], and not accounting for differences between patients [2]....

متن کامل

3D free-breathing cardiac cine imaging with respiratory and cardiac self-gating and 3D motion correction

INTRODUCTION Free-breathing cardiac cine imaging with respiratory and cardiac self-gating provides flexibility and convenience for patient scans. Here we propose a 3D radial cardiac cine imaging technique that improves upon self-gating by adding 3D respiratory motion correction. The 3D respiratory motion signals are derived from multiple projections through the data used for image reconstructio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008