Feasibility of protein A for the oriented immobilization of immunoglobulin on silicon surface for a biosensor with imaging ellipsometry.
نویسندگان
چکیده
The feasibility of using protein A to immobilize antibody on silicon surface for a biosensor with imaging ellipsometry was presented in this study. The amount of human IgG bound with anti-IgG immobilized by the protein A on silicon surface was much more than that bound with anti-IgG immobilized by physical adsorption. The result indicated that the protein A could be used to immobilize antibody molecules in a highly oriented manner and maintain antibody molecular functional configuration on the silicon surface. High reproducibility of the amount of antibody immobilization and homogenous antibody adsorption layer on surfaces could be obtained by this immobilization method. Imaging ellipsometry has been proven to be a fast and reliable detection method and sensitive enough to detect small changes in a molecular monolayer level. The combination of imaging ellipsometry and surface modification with protein A has the potential to be further developed into an efficient immunoassay protein chip.
منابع مشابه
Developing An Ellipsometry-based Biosensor Platform via Covalent and Oriented Coupling of The Nanobody Targeting The Vascular Cell Adhesion Molecule-1 To A Silicon Wafer
Protein immobilization plays a key role in the development of all protein-based biosensors in order to achieve good performances. Conventional techniques such as physical adsorption or randomly chemical coupling usually lead to low activity and reproducibility. Therefore there is an essential need for uniformly oriented, covalent immobilization approaches. In this study, the nanobody targeting ...
متن کاملEnhanced Biosensor Platforms for Detecting the Atherosclerotic Biomarker VCAM1 Based on Bioconjugation with Uniformly Oriented VCAM1-Targeting Nanobodies
Surface bioconjugation of biomolecules has gained enormous attention for developing advanced biomaterials including biosensors. While conventional immobilization (by physisorption or covalent couplings using the functional groups of the endogenous amino acids) usually results in surfaces with low activity, reproducibility and reusability, the application of methods that allow for a covalent and...
متن کاملA Novel Choline Biosensor Based on Immobilization of Enzyme Choline Oxidase on the β-Ga2O3 Nanowires Modified Working Electrode
This article is a report on a novel and high-stability biosensor with minor interference effects of surface modification of working electrode with β-Ga2O3 nanowires (NWs) on choline oxidase biosensor were investigated in an electrochemical detection system. β-Ga2O3 NWs were materialized on the silicon substrate in a catalyst-free growth mechanism. The β-Ga2O<sub...
متن کاملDetection of Cytomegalovirus Antibodies Using a Biosensor Based on Imaging Ellipsometry
BACKGROUND Cytomegalovirus (CMV) is the most common infectious cause of mental disability in newborns in developed countries. There is an urgent need to establish an early detection and high-throughput screening method for CMV infection using portable detection devices. METHODS An antibody analysis method is reported for the detection and identification of CMV antibodies in serum using a bios...
متن کاملA Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biochemical and biophysical methods
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2003