Efficacy of Electronic Foramen Locators in Controlling Root Canal Working Length during Rotary Instrumentation.

نویسندگان

  • Lorena Arruda Parente
  • Martin D Levin
  • Rodrigo Ricci Vivan
  • Ricardo Affonso Bernardes
  • Marco Antonio Hungaro Duarte
  • Bruno Carvalho de Vasconcelos
چکیده

The present study evaluated the efficacy of electronic foramen locators (EFLs) to control root canal working length during rotary instrumentation and to assess possible reliability variations of different working lengths. Forty-eight human mandibular bicuspids were randomly divided in 2 groups according to the used device, Root ZX II (RZX) and Propex II (PRO). They were further subdivided in 2 subgroups according to the root canal preparation level (0.0 and -1.0). Preparation was performed with the Protaper rotary system using a crown-down technique. RZX was employed on its automatic auto-reverse mode (AAR) and PRO was used with the MPAS-10R contra-angle to monitor the preparation. The last used file (F3) was fixed, and the apical portion of the teeth was worn buccolingually, allowing to measure the extent between the file tip and the apical foramen (AF). The precision values of 0.0 mm and -1.0 mm were 100% and 0.0% for RZX, and 100% and 66.7% for PRO, respectively, with a range of ±0.5 mm. Statistical analysis showed no differences between the groups at 0.0 mm. However, at -1.0 mm, RZX showed the poorest results (0.96±0.11 mm), followed by PRO (0.43±0.23 mm). The difference between RZX and PRO was statistically significant. The EFLs were precise in maintaining the working length during rotary preparation when reaching the AF, but when their penetration was limited, both devices showed decreased precision; the RZX AAR failed in all instances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.

AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...

متن کامل

Electronic apex locators.

Prior to root canal treatment at least one undistorted radiograph is required to assess canal morphology. The apical extent of instrumentation and the final root filling have a role in treatment success, and are primarily determined radiographically. Electronic apex locators reduce the number of radiographs required and assist where radiographic methods create difficulty. They may also indicate...

متن کامل

بررسی مشکلات آماده سازی کانال با وسائل دستی و چرخشی نیکل تیتانیوم

Background and Aim: Maintaining the original canal path and safety of canal preparation during instrumentation in curved canals have been subjected to many challenges. The aim of this study was to compare several parameters of root canal preparation using flexmaster rotary and hand used Nickel-Titanium instruments. Materials and Methods: In this experimental study, sixty extracted human teeth w...

متن کامل

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2015