Simulation and optimization of retention in ion chromatography using virtual column 2 software.

نویسندگان

  • John E Madden
  • Matthew J Shaw
  • Greg W Dicinoski
  • Nebojsa Avdalovic
  • Paul R Haddad
چکیده

A new software package, Virtual Column 2, is described for the simulation and optimization of the separation of inorganic anions by ion chromatography (IC). The software uses a limited amount of experimental retention data acquired according to a correct experimental design to predict retention times for analytes over a designated search area of eluent compositions. The experimental retention data are used to solve a new retention model, called the linear solvent strength model, empirical approach (LSSM-EA), which then enables prediction of retention times for all eluent compositions in the search area. The theoretical development of LSSM-EA and the processes used for solving the equations are discussed. Virtual Column 2 can be used for eluents containing one or two competing ions, and the software contains retention databases for up to 33 analytes on the Dionex AS9A-HC, AS4A-SC, and AS14A analytical columns with carbonate-bicarbonate eluents and the Dionex AS10, AS15, and AS16 analytical columns with hydroxide eluents (results for the AS10 and AS15 columns are not discussed in the present study). Virtual Column 2 has been evaluated extensively and is shown to give predicted retention times that in most cases agree with experimentally determined data to within 5%. The software has uses in practical IC method development, education and training in IC, and refinement of existing IC methodology. A free version of this program is available by download at www.virtualcolumn.com.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of HFDS Production from Date Syrup (RESEARCH NOTE)

Fructose is utilized as a common sweetener in many food industries. Today, a large amount of HFCS (high fructose corn syrup, an equilibrium mixture of glucose and fructose) is produced by glucose isomerase, immobilized enzymes from corn starch. There are a lot of date palms in Iran. Date is a favorable source of carbohydrates, and a suitable source for HFDS (high fructose date syrup) production...

متن کامل

Immunoglobulin A Preparation from Human Pooled Plasma Using Plasma Fractionation and Ion Exchange Chromatography

Background: In this study we have prepared the IgA solution from normal human plasma using plasma fractionation and ion exchange chromatography. Materials and Methods: Using fractionation of plasma with cold ethanol (starting with 8% ethanol), fraction III was prepared as a suitable source for IgA preparation. Then it was treated with caprylic acid for separation of impurities. For enrichm...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 23  شماره 

صفحات  -

تاریخ انتشار 2002