Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia
نویسندگان
چکیده
BACKGROUND The relatively simple and cheaper light-emitting diode fluorescent microscopy (LED-FM) was recommended by the World Health Organization (WHO) to replace the conventional tuberculosis (TB) microscopy in both high- and low-volume laboratories. More recently the WHO also endorsed one more technique, Xpert MTB/RIF® assay (Xpert), for improved TB diagnosis particularly among human immunodeficiency virus (HIV)-infected cases. However, the relative performance of both of these tools differs from setting to setting in reference to the conventional TB diagnostics. This study thus aimed to evaluate these tools for TB detection in individuals visiting Ambo Hospital, west-central Ethiopia. METHODS Cross-sectional early-morning sputum samples were collected from presumptive TB patients between January and August 2015. Socio-demographic data were captured using a structured questionnaire. Clinical information was gathered from patients' medical records. The sputum samples were diagnosed using LED-FM, Xpert, concentrated Ziehl-Neelsen (cZN) staining and Lowenstein-Jensen (LJ) culture as the gold standard. Drug sensitivity test (DST) was also conducted. RESULTS Out of 362 sputum samples collected and processed, 36(9.9%) were positive by LED-FM, 42(11.6%) by cZN and 50(13.8%) by Xpert. But, only 340 samples could be declared culture positive or negative for mycobacteria. Of these 340, eight were non-tubercle mycobacteria (NTM). Out of the remaining 332 samples, 45(13.6%) had culture-confirmed TB with 11(24.4%) being HIV co-infected. LED-FM, Xpert and culture detected 54.5% (6/11), 90.9% (10/11) and 100% (11/11) mycobacteria in HIV-positive individuals and 81.3% (26/32), 73.7% (28/38), 78.8% (26/33) and 73.2% (30/41), in HIV negatives respectively. Two samples were rifampicin resistant by both Xpert and DST. The overall sensitivity, specificity, positive and negative predictive values of LED-FM and Xpert were 77.8, 100, 100 and 96; and 93.3, 98, 97.5 and 98.9% respectively. CONCLUSION The data demonstrated the high diagnostic yield of Xpert. LED-FM sensitivity is higher compared to results quoted by recent systematic reviews although it appears to be lower than what was cited in the WHO policy statement (83.6%) during the recommendation of the technology. The high specificity of LED-FM in the study area is encouraging and is expected to boost its reliability and uptake.
منابع مشابه
Rapid Diagnosis of Pulmonary and Extrapulmonary Tuberculosis in HIV-Infected Patients. Comparison of LED Fluorescent Microscopy and the GeneXpert MTB/RIF Assay in a District Hospital in India
HIV-related tuberculosis is difficult to diagnose and is associated with high morbidity and mortality. Recently, the World Health Organization has endorsed the GeneXpert MTB/RIF (Xpert) assay for the diagnosis of pulmonary tuberculosis in HIV-infected patients from developing countries, but information about the use of Xpert for the diagnosis of extrapulmonary tuberculosis is scarce. In this st...
متن کاملModeling the patient and health system impacts of alternative xpert® MTB/RIF algorithms for the diagnosis of pulmonary tuberculosis in Addis Ababa, Ethiopia
BACKGROUND To reduce global tuberculosis (TB) burden, the active disease must be diagnosed quickly and accurately and patients should be treated and cured. In Ethiopia, TB diagnosis mainly relies on spot-morning-spot (SMS) sputum sample smear analysis using Ziehl-Neelsen staining techniques (ZN). Since 2014 targeted use of xpert has been implemented. New diagnostic techniques have higher sensit...
متن کاملEvaluation of Xpert MTB/RIF in detection of pulmonary and extrapulmonary tuberculosis cases in China
Background: To evaluate the performance of Xpert MTB/RIF assay for direct detection of Mycobacterium tuberculosis (Mtb) and rifampin resistance in pulmonary and extrapulmonary tuberculosis (TB) patients in China. Material/Methods: We prospectively enrolled 506 TB patients to evaluate sensitivity and specificity of Xpert MTB/ RIF by comparing with Mtb culture, fluorescent staining smear microsco...
متن کاملRapid Diagnosis of Childhood Pulmonary Tuberculosis by Xpert MTB/RIF Assay Using Bronchoalveolar Lavage Fluid
In order to evaluate the diagnostic accuracy of the Xpert MTB/RIF assay on childhood pulmonary tuberculosis (PTB) using bronchoalveolar lavage fluid (BALF), we evaluated the sensitivity, specificity, positive predictive value, and negative predictive value of Xpert MTB/RIF assay using BALF in comparison with acid-fast bacilli (AFB) microscopy and Mycobacterium tuberculosis (MTB) culture for dia...
متن کاملUse of the Xpert® MTB/RIF assay for diagnosing pulmonary tuberculosis comorbidity and multidrug-resistant TB in obstetrics and gynaecology inpatient wards at the University Teaching Hospital, Lusaka, Zambia
OBJECTIVES In high-tuberculosis (TB)-endemic countries, comorbidity of pulmonary TB in hospitalised patients with non-communicable diseases is well documented. In this study, we evaluated the use of the Xpert(®) MTB/RIF assay for the detection of concomitant pulmonary TB in patients admitted to the University Teaching Hospital, Lusaka, Zambia, with a primary obstetric or gynaecological conditio...