Image-based registration for synthetic aperture holography.
نویسندگان
چکیده
High pixel count apertures for digital holography may be synthesized by scanning smaller aperture detector arrays. Characterization and compensation for registration errors in the detector array position and pitch and for phase instability between the reference and object field is a major challenge in scanned systems. We use a secondary sensor to monitor phase and image-based registration parameter estimators to demonstrate near diffraction-limited resolution from a 63.4 mm aperture synthesized by scanning a 5.28 mm subaperture over 144 transverse positions. We demonstrate 60 μm resolution at 2 m range.
منابع مشابه
Synthetic aperture microscopy based on referenceless phase retrieval with an electrically tunable lens.
Phase imaging microscopy, based either on holography or nonholographic methods such as phase retrieval, has seen considerable attention recently. Phase retrieval offers the advantage of being free of a reference arm and enables a more stable and compact setup. We present an optical setup that provides enhanced resolution by implementing synthetic aperture imaging based on phase retrieval using ...
متن کاملSynthetic Aperture Digital Holography
Synthetic aperture is a well-known super-resolution technique which extends the resolution capabilities of an imaging system beyond the theoretical Rayleigh limit dictated by the system's actual aperture. Using this technique, several patterns acquired by an aperture-limited system, from various locations, are tiled together to one large pattern which could be captured only by a virtual system ...
متن کاملHigh-resolution synthetic-aperture digital holography with digital phase and pupil correction.
A 218 mega-pixel synthetic aperture was collected by raster scanning a CCD detector in a digital holography imaging experiment. Frames were mosaicked together using a two-step cross-correlation registration. Phase correction using sharpness metrics were utilized to achieve diffraction-limited resolution.
متن کاملA Robust SAR NLFM Waveform Selection Based on the Total Quality Assessment Techniques
Design, simulation and optimal selection of cosine-linear frequency modulation waveform (CNLFM) based on correlated ambiguity function (AF) method for the purpose of Synthetic Aperture Radar (SAR) is done in this article. The selected optimum CNLFM waveform in contribution with other waveforms are applied directly into a SAR image formation algorithm (IFA) and their quality effects performance ...
متن کاملSuperresolved phase-shifting Gabor holography by CCD shift
Holography in the Gabor regime is restricted to weak diffraction assumptions. Otherwise, diffraction prevents an accurate recovery of the object’s complex wavefront. We have recently proposed a modified Gabor-like setup to extend Gabor’s concept to any sample provided that it be non-diffusive. However, the resolution of the final image becomes limited as a consequence of the additional elements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 12 شماره
صفحات -
تاریخ انتشار 2011