Evaluation of New Calibrated Pulse-Wave Analysis (VolumeViewTM/EV1000TM) for Cardiac Output Monitoring Undergoing Living Donor Liver Transplantation

نویسندگان

  • MiHye Park
  • Sangbin Han
  • Gaab Soo Kim
  • Mi Sook Gwak
چکیده

BACKGROUND Intrapulmonary thermodilution technique using a pulmonary artery catheter is widely used for measuring cardiac output (CO) in patients undergoing liver transplantation. However, its invasiveness and associated complications have led to an interest in less invasive modalities. Thus, we aimed to evaluate whether the new calibrated pulse-wave analysis method monitoring (VolumeViewTM/EV1000TM) is interchangeable with intrapulmonary thermodilution technique. METHODS Twenty-eight patients undergoing living donor liver transplantation were enrolled in this prospective observational study. COs were recorded automatically by the two devices and compared simultaneously at 10-minute intervals. The agreement of absolute CO values and the tracking ability of CO changes trends were compared. A Bland-Altman analysis with percentage errors and concordance rate for trend analysis using both a 4-quadrant plot and a polar plot were performed on the data. RESULTS A total of 375 paired datasets from 25 patients were included in analysis. COs measured by intrapulmonary thermodilution ranged from 3.8-13.7 L/min. The mean CO difference between the two techniques was 0.57 L/min, and the 95% limits of agreement were -0.98 L/min to 2.12 L/min with a percentage error of 42.3%. The percentage errors in the dissection, anhepatic, and reperfusion phase were 30.5%, 31.7%, and 27.4%, respectively. The concordance rate between the two techniques was 78.4%. CONCLUSION The calibrated pulse-wave analysis and intrapulmonary thermodilution failed to show acceptable interchangeability in terms of both estimating CO and tracking CO changes during living donor liver transplantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients

Editor’s key points † Previously, continuous cardiac output (CO) measurement techniques required the insertion of a pulmonary artery catheter. † The PiCCO and VolumeView systems use arterial pulse contour analysis for continuous CO measurement. † Both require calibration with transpulmonary thermodilution (TPTD) measurements using a central venous catheter. † The current study compared the perf...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation.

PURPOSE The PiCCO System is a relatively new device allowing intermittent cardiac output monitoring by aortic transpulmonary thermodilution technique (Aorta intermittent) and continuous cardiac output monitoring by pulse contour analysis (Aorta continuous). The objective of this study was to assess the level of agreement of Aorta intermittent and Aorta continuous with intermittent (PA intermitt...

متن کامل

Orthotopic liver transplantation from cardiac death donors in the mouse: a new model and evaluation of cardiac death time

Objective(s): The goal of this research was to develop a mouse orthotopic liver transplantation (LTx) model from donor-after-cardiac-death (DCD) grafts. Materials and Methods: Mice were randomly assigned to the experimental group or the sham group. The mice in the experimental group were divided into three groups according to the warm ischemia time (WIT) of liver graft: normal LTx, WIT 30 minut...

متن کامل

Bioreactance Is Not Interchangeable with Thermodilution for Measuring Cardiac Output during Adult Liver Transplantation

BACKGROUND Thermodilution technique using a pulmonary artery catheter is widely used for the assessment of cardiac output (CO) in patients undergoing liver transplantation. However, the unclearness of the risk-benefit ratio of this method has led to an interest in less invasive modalities. Thus, we evaluated whether noninvasive bioreactance CO monitoring is interchangeable with thermodilution t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016