Comparison of vertebroplasty using directional versus straight needle
نویسندگان
چکیده
BACKGROUND Percutaneous vertebroplasty is a minimally invasive procedure that can be performed to treat pain and immobility associated with vertebral compression fractures. Previous studies have shown that a single injection can achieve adequate fill across the midline of the vertebral body. PURPOSE To compare the radiological outcomes of using a novel steerable needle with using a conventional, straight needle in unipedicular vertebroplasty. MATERIAL AND METHODS Data were collected from 19 patients who were operated at our institute between 1 September 2010 and 31 March 2011. Outcomes were measured in terms of radiological evidence of midline crossing of cement. The available pre- and postoperative pain scores and complications were reviewed. Student's t-test was used to compare mean cement projection across the midline in both groups with P < 0.05 considered to be statistically significant. RESULTS Mean fill across the midline was significantly greater with the steerable needle (58%) compared with the straight needle (35%) (P = 0.046). Cement leakage was higher with the steerable needle (44% versus 30%); however no clinical complications were reported in either group. CONCLUSION Percutaneous vertebroplasty using a directional needle is an excellent example of advancement and refinement in spinal surgery without increased clinical risk. Our results indicate that the novel technique can potentially provide better radiological outcomes when compared with a straight needle. A larger, randomized multicenter prospective trial would be valuable in confirming these findings.
منابع مشابه
A Comparative Study on Using Coiled Versus Straight Swan-Neck Tenckhoff Catheters in Patients Undergoing Peritoneal Dialysis
The key to successful long-term peritoneal dialysis (PD) is permanent and safe access to peritoneal cavity. The two most commonly used Tenckoff catheters for PD are the straight and coiled catheters. The present study was undertaken to assess the catheter survival, catheter associated infections, and all cause mortality and to compare the straight with coiled catheters in PD. During April 1997-...
متن کاملRadiation dose to the operator during vertebroplasty: prospective comparison of the use of 1-cc syringes versus an injection device.
BACKGROUND AND PURPOSE Percutaneous vertebroplasty procedures require relatively long durations of fluoroscopic guidance, which might lead to substantial radiation dose to operators. Specialized injection devices have been proposed to limit operator exposure. Our purpose was to compare the radiation dose to the operator's hands during vertebroplasty when using 1-cc syringes versus that when usi...
متن کاملVertebroplasty in the mid- and upper thoracic spine.
BACKGROUND AND PURPOSE Vertebroplasty performed in the mid- and upper thoracic spine presents technical challenges that differ from those in the lower thoracic and lumbar region. We herein report results of percutaneous vertebroplasty for treatment of painful, osteoporotic compression fractures in the mid- and upper thoracic spine. METHODS Retrospective chart review identified vertebroplasty ...
متن کاملFluoroscopically Guided C2 Percutaneous Vertebroplasty: A Surgical Technique Note on an Anterior Ascending Approach.
BACKGROUND C2 vertebroplasty is more challenging than transpedicular percutaneous vertebroplasty in the thoracic and lumbar spine. OBJECTIVE We report an anterior ascending approach for C2 percutaneous vertebroplasty to avoid potential injury to vital structures surrounding the C2 vertebra. STUDY DESIGN A technique note with 5 consecutive cases. SETTING Neurosurgery department of a univer...
متن کاملDevelopment of Mathematical Model for Controlling the Drilling Parameters with a Screw Downhole Motor
Article presents results of study on possibility of increasing the efficiency of drilling directional straight sections of wells using screw downhole motors (SDM) with a combined method of drilling with rotation of drilling string (DS). Goal is to ensure steady-state operation of SDM with simultaneous rotation of DS by reducing the amplitude of oscillations with adjusting the parameters of dril...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -