Purpose. To introduce a new anterior segment optical coherence tomography parameter, trabecular-iris circumference volume (TICV), which measures the integrated volume of the peripheral angle, and establish a reference range in normal, open angle eyes. Methods. One eye of each participant with open angles and a normal anterior segment was imaged using 3D mode by the CASIA SS-1000 (Tomey, Nagoya, Japan). Trabecular-iris space area (TISA) and TICV at 500 and 750 µm were calculated. Analysis of covariance was performed to examine the effect of age and its interaction with spherical equivalent. Results. The study included 100 participants with a mean age of 50 (±15) years (range 20-79). TICV showed a normal distribution with a mean (±SD) value of 4.75 µL (±2.30) for TICV500 and a mean (±SD) value of 8.90 µL (±3.88) for TICV750. Overall, TICV showed an age-related reduction (P = 0.035). In addition, angle volume increased with increased myopia for all age groups, except for those older than 65 years. Conclusions. This study introduces a new parameter to measure peripheral angle volume, TICV, with age-adjusted normal ranges for open angle eyes. Further investigation is warranted to determine the clinical utility of this new parameter.
منابع مشابه
Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery
Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome...
متن کاملAgreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
Purpose To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). Methods Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and...
متن کاملLow Iris and Anterior Chamber Volume Associated with Deepening after Laser Peripheral Iridotomy in Primary Angle Closure Suspects
Purpose: To evaluate the associa on between baseline ocular variables and the opening of the anterior chamber angle by laser peripheral iridotomy (LPI) in primary angle closure suspects (PACS) using a new Fourier-domain swept-source anterior segment op cal coherence tomography (FD-ASOCT). Method: Sixty-six PACS eyes of 41 individuals were included in this prospec ve interven onal case series. A...
متن کاملEstablishing Age-Adjusted Reference Ranges for Iris-Related Parameters in Open Angle Eyes with Anterior Segment Optical Coherence Tomography
PURPOSE Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). METHODS Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken wi...
متن کاملTemporal ocular coherence tomography-measured changes in anterior chamber angle and diurnal intraocular pressure after laser iridoplasty: IMPACT study
AIMS To evaluate temporal change in anterior chamber angle anatomy following argon laser peripheral iridoplasty (ALPI) in eyes with occludable angles postlaser peripheral iridotomy (LPI) compared with control eyes. Additionally, the effect on diurnal intraocular pressure (DIOP) fluctuation (maximum-minimum IOP) was investigated. METHODS Twenty-two patients with bilateral primary angle closure...
متن کاملذخیره در منابع من