Influence of cellulose triacetate hemodialyzers on vancomycin pharmacokinetics.

نویسندگان

  • L S Welage
  • N A Mason
  • E J Hoffman
  • R M Odeh
  • J Dombrouski
  • J A Patel
  • R D Swartz
چکیده

This study was designed to evaluate the pharmacokinetics of vancomycin during hemodialysis with cellulose triacetate (CT) high-flux dialyzers and to assess the influence of membrane surface area on intradialytic clearance. In a randomized crossover fashion, the pharmacokinetics of vancomycin were evaluated during dialysis with the CT 110 and CT 190 membranes. Six hemodialysis patients received 1 g of vancomycin immediately after the completion of a dialysis session, and subsequently, blood samples were obtained over a 5-day study period. On Day 3 subjects were dialyzed with CT 110 or CT 190 membranes. The mean intradialytic clearance of vancomycin was 56.7 +/- 7.5 and 100.70 +/- 10.7 mL/min with the CT 110 and CT 190 membranes, respectively (P < 0.05). Significant rebound in vancomycin serum concentrations occurred after dialysis; this rebound appeared to be complete 3 h postdialysis. On the basis of postrebound concentrations, the apparent percent removal of vancomycin was 23.6 +/- 1.2 and 25.2 +/- 8.6% for CT 110 and CT 190 membranes, respectively (not significant). Vancomycin is significantly cleared during dialysis with cellulose triacetate membranes, and its clearance is dependent on membrane surface area. Although a small supplemental dose of vancomycin could be administered after dialysis to replace drug lost during dialysis, it may be more efficient to give a larger dose of vancomycin after several dialysis periods. The determination of vancomycin removal can be used to estimate vancomycin serum concentrations as well as dosage requirements. This in conjunction with serum concentration monitoring can be used to optimize vancomycin dosing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vancomycin mass transfer characteristics of high-flux cellulosic dialysers.

BACKGROUND In comparison to conventional haemodialysis membranes, highly permeable membranes allow a broader spectrum of solute removal, including enhanced elimination of vancomycin (1448 Daltons). However, the mass transfer characteristics of vancomycin removal by highly permeable membranes have not been adequately assessed. An understanding of vancomycin's predominant dialytic mass transfer m...

متن کامل

Clearance of vancomycin during high-efficiency hemodialysis.

BACKGROUND Vancomycin is commonly used for the treatment of MRSA infections in critically ill patients with renal diseases. Vancomycin is mainly eliminated through the kidney. Its excretion is therefore substantially reduced in severe renal impaired patients. Although several studies have demonstrated that significant amounts of vancomycin are removed during High-Flux/High-Efficiency Hemo Dialy...

متن کامل

Thermal Degradation of Cellulosic Materials

Fortisan, cellulose triacetate, and NOroxidized cellulose were pyrolyzed in a vacuum in the temperature range 1800 to 465 0 C. Cotton cellulose and cellulose t ri acetate were also pyrolyzed in nitrogen at atmospheric pressure. The tar yields were in the decreasing order from: Cotton, Fortisan, cellulose triacetate, and oxidized cellulose. The other volatiles consisted mainly of acetic acid, ca...

متن کامل

Potentiometric ion- and bio-selective electrodes based on asymmetric cellulose acetate membranes.

The potentiometric response properties of ammonium-, carbonate-, and proton-selective electrodes prepared by incorporating appropriate neutral carriers within novel asymmetric cellulose acetate membranes are reported. The membranes are formed by first casting a thin layer of cellulose triacetate without carrier, hydrolyzing one side of this film with base, and then on the other side casting a s...

متن کامل

Longitudinal hemodiafilter performance in modeled continuous renal replacement therapy.

BACKGROUND/AIMS With advanced anticoagulation, many institutions operate continuous renal replacement therapy (CRRT) circuits longer than manufacturers' recommendations. This extended use may change hemodiafilter performance and clearance properties. However, hemodiafilter performance over time has not been assessed. We investigated solute clearance over time in modeled CRRT. METHODS In vitro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1995